Deemed-to-Satisfy Provision · NCC 2022 Volume One

J3D11 External winter glazing of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Part J3 Elemental provisions for a sole-occupancy unit of a Class 2 building or a Class 4 part of a building

Open J3D11 on NCC Online ↗
Varied in NSW. Check the variation for your state.

(1) In climate zones 2 to 8, the ratio of the conductance (CU) and solar heat gain (CSHGC) of the glazing of each storey, including any mezzanine, of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building must—

not exceed the allowance obtained from Table J3D11a; and

be calculated in accordance with the following formula:

[formula] (2) In the formula at (1)(b)—

[formula] = the area of each glazing element; and

[formula] = the Total System U-Value of each glazing element; and

[formula] = the Total System SHGC for each glazing element, not exceeding 0.7; and

[formula] = the winter exposure factor for each glazing element obtained from Table J3D11b, J3D11c, J3D11d, J3D11e, J3D11f or J3D11g; and

[formula] = the bedroom conductance factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m; and

[formula] = the orientation sector conductance factor obtained from Table J3D11n; and

[formula] = the room type factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m; and

[formula] = the bedroom solar heat gain factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m; and

[formula] = the frame factor obtained from Table J3D11o, J3D11p, J3D11q, J3D11r, J3D11s or J3D11t for each glazing element; and

[formula] = the floor factor obtained from Table J3D11h, J3D11i, J3D11j, J3D11k, J3D11l or J3D11m for each glazing element.

(3) For the purpose of J3D11—

orientation sectors must be determined in accordance with Figure 13.3.2a of the ABCB Housing Provisions; and

P/H must be determined in accordance with Figure S37C7; and

For P/H between those in Tables J3D11b, J3D11c, J3D11d, J3D11e, J3D11f and J3D11g, either use the next highest P/H or interpolate.

Table J3D11a Maximum conductance to solar heat gain ratio (CU/CSHGC)

Climate zone

Maximum conductance to solar heat gain ratio (CU/CSHGC)

2

16.95

3

19.88

4

13.34

5

11.83

6

6.27

7

12.90

8

12.90

Table J3D11b Orientation sector winter exposure factor (EW): climate zone 2

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.49

1.61

1.23

0.96

0.68

1.03

1.37

1.71

0.05

1.44

1.53

1.14

0.81

0.57

0.90

1.27

1.64

0.10

1.38

1.48

1.09

0.76

0.53

0.85

1.22

1.55

0.20

1.21

1.32

0.97

0.69

0.50

0.75

1.10

1.39

0.40

1.00

1.06

0.77

0.57

0.42

0.63

0.92

1.14

0.60

0.83

0.87

0.69

0.50

0.37

0.55

0.77

0.96

0.80

0.62

0.69

0.56

0.43

0.35

0.50

0.66

0.79

1.00

0.43

0.59

0.46

0.41

0.33

0.43

0.56

0.65

1.20

0.26

0.47

0.40

0.36

0.31

0.40

0.53

0.53

1.40

0.22

0.40

0.33

0.33

0.29

0.38

0.47

0.44

1.60

0.18

0.32

0.31

0.33

0.28

0.35

0.39

0.39

1.80

0.15

0.28

0.27

0.31

0.26

0.33

0.35

0.32

2.00

0.12

0.21

0.24

0.29

0.26

0.33

0.33

0.31

Table J3D11c Orientation sector winter exposure factor (EW): climate zone 3

P/H

North

North east

East

South east

South

South west

West

North west

0.00

0.90

1.10

0.88

0.69

0.50

0.58

0.67

0.91

0.05

0.89

1.06

0.82

0.60

0.44

0.51

0.64

0.89

0.10

0.83

1.01

0.78

0.58

0.42

0.49

0.61

0.84

0.20

0.74

0.90

0.70

0.52

0.40

0.44

0.55

0.76

0.40

0.59

0.74

0.60

0.43

0.36

0.37

0.47

0.63

0.60

0.44

0.57

0.48

0.39

0.34

0.32

0.38

0.51

0.80

0.30

0.45

0.43

0.34

0.30

0.30

0.32

0.41

1.00

0.20

0.38

0.35

0.30

0.28

0.28

0.29

0.33

1.20

0.14

0.29

0.31

0.28

0.28

0.25

0.24

0.28

1.40

0.11

0.26

0.25

0.26

0.26

0.23

0.21

0.24

1.60

0.08

0.23

0.24

0.24

0.24

0.21

0.20

0.20

1.80

0.07

0.16

0.19

0.24

0.24

0.19

0.17

0.18

2.00

0.06

0.16

0.18

0.21

0.24

0.19

0.15

0.16

Table J3D11d Orientation sector winter exposure factor (EW): climate zone 4

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.58

1.66

1.16

0.93

0.70

0.78

0.85

1.38

0.05

1.54

1.60

1.06

0.79

0.58

0.66

0.79

1.32

0.10

1.53

1.54

1.04

0.74

0.56

0.62

0.75

1.28

0.20

1.30

1.41

0.94

0.67

0.50

0.56

0.68

1.15

0.40

1.18

1.20

0.78

0.57

0.44

0.48

0.58

0.99

0.60

0.98

0.99

0.69

0.50

0.38

0.42

0.49

0.81

0.80

0.85

0.81

0.60

0.45

0.36

0.38

0.44

0.68

1.00

0.68

0.73

0.52

0.41

0.32

0.34

0.37

0.58

1.20

0.49

0.56

0.46

0.36

0.32

0.32

0.34

0.50

1.40

0.38

0.52

0.42

0.33

0.30

0.30

0.30

0.42

1.60

0.27

0.45

0.39

0.33

0.28

0.28

0.26

0.37

1.80

0.21

0.39

0.35

0.31

0.28

0.26

0.24

0.32

2.00

0.19

0.35

0.31

0.29

0.26

0.24

0.22

0.26

Table J3D11e Orientation sector winter exposure factor (EW): climate zone 5

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.61

1.34

1.08

0.87

0.67

0.76

0.85

1.23

0.05

1.56

1.29

0.98

0.74

0.56

0.64

0.78

1.17

0.10

1.56

1.23

0.92

0.69

0.54

0.62

0.75

1.14

0.20

1.30

1.10

0.83

0.63

0.49

0.54

0.67

1.03

0.40

1.19

0.91

0.69

0.54

0.41

0.47

0.55

0.86

0.60

0.97

0.75

0.56

0.47

0.38

0.41

0.47

0.70

0.80

0.78

0.62

0.49

0.42

0.34

0.37

0.42

0.57

1.00

0.64

0.47

0.39

0.38

0.32

0.33

0.36

0.49

1.20

0.43

0.42

0.35

0.36

0.31

0.31

0.29

0.39

1.40

0.32

0.31

0.29

0.34

0.29

0.29

0.28

0.33

1.60

0.22

0.27

0.27

0.31

0.25

0.25

0.23

0.28

1.80

0.18

0.23

0.22

0.29

0.25

0.25

0.20

0.25

2.00

0.14

0.17

0.21

0.27

0.25

0.23

0.19

0.19

Table J3D11f Orientation sector winter exposure factor (EW): climate zone 6

P/H

North

North east

East

South east

South

South west

West

North west

0.00

3.04

2.50

1.52

1.51

1.51

1.63

1.76

2.75

0.05

2.94

2.36

1.39

1.28

1.26

1.38

1.62

2.61

0.10

2.91

2.28

1.33

1.21

1.19

1.30

1.52

2.55

0.20

2.50

2.05

1.18

1.08

1.05

1.16

1.40

2.34

0.40

2.29

1.77

1.01

0.91

0.91

0.98

1.20

1.98

0.60

1.95

1.51

0.86

0.77

0.81

0.83

1.04

1.71

0.80

1.73

1.28

0.72

0.71

0.74

0.80

0.92

1.42

1.00

1.38

1.02

0.65

0.64

0.67

0.69

0.78

1.24

1.20

1.12

0.95

0.55

0.61

0.60

0.65

0.72

1.04

1.40

0.85

0.72

0.49

0.54

0.60

0.62

0.64

0.93

1.60

0.70

0.65

0.42

0.50

0.56

0.54

0.56

0.79

1.80

0.51

0.53

0.40

0.47

0.53

0.51

0.54

0.72

2.00

0.40

0.47

0.38

0.44

0.49

0.51

0.48

0.58

Table J3D11g Orientation sector winter exposure factor (EW): climate zones 7 and 8

P/H

North

North east

East

South east

South

South west

West

North west

0.00

1.66

1.53

0.90

0.82

0.74

0.78

0.83

1.43

0.05

1.61

1.47

0.83

0.69

0.61

0.66

0.76

1.37

0.10

1.61

1.44

0.79

0.64

0.59

0.62

0.73

1.34

0.20

1.51

1.34

0.73

0.58

0.53

0.55

0.66

1.22

0.40

1.30

1.17

0.63

0.49

0.44

0.47

0.55

1.07

0.60

1.19

1.02

0.54

0.43

0.40

0.41

0.48

0.91

0.80

1.02

0.88

0.48

0.39

0.36

0.37

0.43

0.79

1.00

0.93

0.78

0.44

0.34

0.34

0.33

0.37

0.67

1.20

0.73

0.66

0.37

0.32

0.32

0.31

0.33

0.60

1.40

0.66

0.64

0.36

0.30

0.29

0.29

0.30

0.46

1.60

0.51

0.46

0.32

0.28

0.27

0.25

0.28

0.43

1.80

0.42

0.44

0.26

0.26

0.27

0.25

0.25

0.37

2.00

0.31

0.37

0.26

0.24

0.25

0.25

0.22

0.31

Table J3D11h Conductance and radiation factors: climate zone 2

Type of factor

Factor

Bedroom conduction weighting factor (BC)

0.43

Room type multiplier (for bedroom and unconditioned areas) (RW)

1.00

Bedroom solar heat gain weighting factor (BSW)

0.40

Floor factor for tiled or vinyl covered floors (HW)

1.02

Floor factor for other than tiled or vinyl covered floors (HW)

0.96

Table J3D11i Conductance and radiation factors: climate zone 3

Type of factor

Factor

Bedroom conduction weighting factor (BC)

0.42

Room type multiplier (for bedroom and unconditioned areas) (RW)

1.00

Bedroom solar heat gain weighting factor (BSW)

1.28

Floor factor for tiled or vinyl covered floors (HW)

1.02

Floor factor for other than tiled or vinyl covered floors (HW)

0.97

Table J3D11j Conductance and radiation factors: climate zone 4

Type of factor

Factor

Bedroom conduction weighting factor (BC)

0.70

Room type multiplier (for bedroom and unconditioned areas) (RW)

1.00

Bedroom solar heat gain weighting factor (BSW)

0.60

Floor factor for tiled or vinyl covered floors (HW)

1.04

Floor factor for other than tiled or vinyl covered floors (HW)

0.92

Table J3D11k Conductance and radiation factors: climate zone 5

Type of factor

Factor

Bedroom conduction weighting factor (BC)

0.63

Room type multiplier (for bedroom and unconditioned areas) (RW)

1.10

Bedroom solar heat gain weighting factor (BSW)

0.81

Floor factor for tiled or vinyl covered floors (HW)

1.03

Floor factor for other than tiled or vinyl covered floors (HW)

0.93

Table J3D11l Conductance and radiation factors: climate zone 6

Type of factor

Factor

Bedroom conduction weighting factor (BC)

0.81

Room type multiplier (for bedroom and un

Tables

Changed in NCC 2025. See NCC 2025 Volume One J3D11, or show what changed.

(1) In climate zones 2 to 8, the ratio of … of the glazing of each storey, including any mezzanine, of a sole-occupancy unit of a Class 2 building or a Class 4 part of a building must — not … Provisions; and P/H must be determined in accordance with Figure S37C7; S37C7a; and For P/H between those in Tables J3D11b, J3D11c, J3D11d, … weighting factor (BC) 0.81 Room type multiplier (for bedroom and un unconditioned areas) (RW) 1.00 Bedroom solar hea

Removed words are struck through; added words are highlighted. Comparison of the text only.

Can't meet J3D11? A Performance Solution must meet the Performance Requirements it satisfies: J1P1, J1P2, J1P3, J1P4. Start a Performance Solution →

State and territory variations all clauses side by side →

Clauses referred to

Defined terms used