TAS G1D2 Swimming pools
Part G1 Minor structures and components · varies G1D2 Swimming pools
Delete clause G1D2 and insert TAS G1D2 as follows:
(1) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with AS 1926.1 and AS 1926.2.
(2) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.
(3) Swimming pools for the use of the public, a club, or an association, or in connection with Class 3, 5, 6, 7, 8 or 9 buildings must—
be constructed of durable materials with smooth finishes; and
have sides vertical; and
in that part of the pool where the water depth is not more than 1.5 m, have the bottom or floor slope not steeper than 1 vertical to 15 horizontal; and
have the depth of water marked clearly and conspicuously on each side of the pool (at the shallow end and at the deep end); and
not have diving boards installed where the water depth is less than 3.5 m; and
have scum-gutters with opening not less than 150 mm if they are to provide hand-holds; and
have the floor or bottom of the pool, except for the guide lines, of such colours that the light reflectance is not less than 60%.
(4) For a public swimming pool or pool in which competitions are held—
all steps into the pool must be recessed; and
fittings must not project into the water area; and
piping must not be bracketed to the sides to provide hand-holds; and
surrounding concourses must be provided not less than 2 m wide, with a suitable non-slip surface, graded away from the pool and drained to waste; and
dressing rooms with sanitary accommodation must be so located that bathers pass through that accommodation enroute to the swimming pool.
(5) If the volume of a swimming pool exceeds 15 m3—
an adequate water recirculation, disinfection and filtration system must be installed; and
(the inlet and outlet openings in a swimming pool for the purpose of water recirculation must be so located that water movement is continuous from inlet to outlet; and
recirculation of water in a swimming pool must be so designed that the pool contents are recirculated not less than once in the period shown in TAS Table G1D2a; and
water filtration rates must not exceed 12 250 L/m2 of sand filter bed per hour, or an equivalent rate in other filter media.
(6) Where no other suitable sanitary accommodation is provided, sanitary facilities must be provided in accordance with TAS Table G1D2b.
(7) Where no other suitable shower facilities are provided, showers must be provided so that each shower serves up to 40 persons.
Insert TAS table (G1D2a) G1D2 as follows:
TAS Table G1D2a: Recirculation of water in swimming pools
Pool type
Period (hours)
Outdoor swimming pool
6
Indoor swimming pool
4
Wading pool
2
Insert TAS table (G1D2b) G1D2 as follows:
TAS Table G1D2b: Sanitary facilities at swimming pools
Gender
Maximum number served by 1 closet fixture
Maximum number served by each extra closet fixture
Maximum number served by 1 urinal
Maximum number served by each extra urinal
Maximum number served by 1 wash basin
Maximum number served by each extra wash basin
Males
60
60
60
60
60
60
Females
40
40
N/A
N/A
60
60
The national clause
Other states and territories
- VIC Delete clause G1D2 and insert VIC G1D2 as follows: (1) A swimming pool associated with a children’s service, with a…
- NSW Delete clause G1D2 and insert NSW G1D2 as follows: (1) NSW G1D2(2) applies to the technical construction requirements…
- NT This clause been deliberately left blank Barriers and fences for swimming pools are regulated by the Northern…
- QLD This clause been deliberately left blank Barriers and fences for swimming pools are regulated by the Building Act 1975…
- SA Delete clause G1D2 and insert SA G1D2 as follows: (1) A swimming pool with a depth of water more than 300 mm and which…