Tasmania variation · NCC 2025 Volume One

TAS G1D2 Swimming pools

TAS Part G1 Minor structures and components · varies G1D2 Swimming pools

Open on NCC Online ↗

Delete clause G1D2 and insert TAS G1D2 as follows:

(1) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with AS 1926.1 and AS 1926.2.

(2) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.

(3) Swimming pools for the use of the public, a club, or an association, or in connection with Class 3, 5, 6, 7, 8 or 9 buildings must—

be constructed of durable materials with smooth finishes; and

have sides vertical; and

in that part of the pool where the water depth is not more than 1.5 m, have the bottom or floor slope not steeper than 1 vertical to 15 horizontal; and

have the depth of water marked clearly and conspicuously on each side of the pool (at the shallow end and at the deep end); and

not have diving boards installed where the water depth is less than 3.5 m; and

have scum-gutters with opening not less than 150 mm if they are to provide hand-holds; and

have the floor or bottom of the pool, except for the guide lines, of such colours that the light reflectance is not less than 60%.

(4) For a public swimming pool or pool in which competitions are held—

all steps into the pool must be recessed; and

fittings must not project into the water area; and

piping must not be bracketed to the sides to provide hand-holds; and

surrounding concourses must be provided not less than 2 m wide, with a suitable non-slip surface, graded away from the pool and drained to waste; and

dressing rooms with sanitary accommodation must be so located that bathers pass through that accommodation enroute to the swimming pool.

(5) If the volume of a swimming pool exceeds 15 m3—

an adequate water recirculation, disinfection and filtration system must be installed; and

(the inlet and outlet openings in a swimming pool for the purpose of water recirculation must be so located that water movement is continuous from inlet to outlet; and

recirculation of water in a swimming pool must be so designed that the pool contents are recirculated not less than once in the period shown in TAS Table G1D2a; and

water filtration rates must not exceed 12 250 L/m2 of sand filter bed per hour, or an equivalent rate in other filter media.

(6) Where no other suitable sanitary accommodation is provided, sanitary facilities must be provided in accordance with TAS Table G1D2b.

(7) Where no other suitable shower facilities are provided, showers must be provided so that each shower serves up to 40 persons.

Insert TAS table (G1D2a) G1D2 as follows:

TAS Table G1D2a: Recirculation of water in swimming pools

Pool type

Period (hours)

Outdoor swimming pool

6

Indoor swimming pool

4

Wading pool

2

Insert TAS table (G1D2b) G1D2 as follows:

TAS Table G1D2b: Sanitary facilities at swimming pools

Gender

Maximum number served by 1 closet fixture

Maximum number served by each extra closet fixture

Maximum number served by 1 urinal

Maximum number served by each extra urinal

Maximum number served by 1 wash basin

Maximum number served by each extra wash basin

Males

60

60

60

60

60

60

Females

40

40

N/A

N/A

60

60

Same wording in NCC 2022 Volume One. See NCC 2022 Volume One TAS G1D2.