Tasmania variation · NCC 2022 Volume One
TAS I15D2 Floors
TAS Part I15 Premises for lead processing
(1) The floor of every work place where a lead process is used must be—
so constructed of concrete or other suitable material as to be smooth and impervious to fluids; and
graded and properly drained to permit flushing with water.
(2) The mater of which the floor is constructed must be applied to the walls to a height of not less than 75 mm in such a fashion that the angle between the walls and the floor is coved for easy cleaning.