Tasmania variation · NCC 2025 Volume One

TAS I15D2 Floors

TAS Part I15 Premises for lead processing

Open on NCC Online ↗

Delete clause I15D2 and insert TAS I15D2 as follows:

(1) The floor of every work place where a lead process is used must be—

so constructed of concrete or other suitable material as to be smooth and impervious to fluids; and

graded and properly drained to permit flushing with water.

(2) The mater of which the floor is constructed must be applied to the walls to a height of not less than 75 mm in such a fashion that the angle between the walls and the floor is coved for easy cleaning.

Changed since NCC 2022. See NCC 2022 Volume One TAS I15D2, or show what changed.

Delete clause I15D2 and insert TAS I15D2 as follows: (1) The floor of every work place where a lead … the walls and the floor is coved for easy cleaning.

Removed words are struck through; added words are highlighted. Comparison of the text only.