VIC I5D3 Temporary tiered seating, concourses and embankments
VIC Part I5 Places of public entertainment
Temporary tiered seating, concourse and embankments must be designed and constructed as follows:
Temporary tiered seating, concourse and embankments must comply with the Deemed-to-Satisfy Provisions of Section B, Section D and I1D4(a)(ii), (iii) and (b).
The maximum slope of tiered seating must not exceed 34 degrees measured from the horizontal plane.
Aisles must be evenly spaced throughout the structure and have—
a minimum width of 1 m; and
the aggregate of aisle widths leading to an exit must be not less than the required width of that exit; and
no one aisle may serve more than—
120 patrons where individual seating with backs is provided; or
200 patrons in any other case.
When applying the balustrading requirements of the Deemed-to-Satisfy Provisions of Section D, the height of plat balustrading that directly abuts seating (i.e. with no aisle between the seat and the balustrading) must be measured from the plat or seat base whichever in the higher.
Transverse aisles must be provided at a horizontal distance of not more than 10 m between any row of seats.
All individual moveable seats must be—
fixed in groups of not less than four; and
not used in stepped or ramped seating areas.
For any spectators’ embankment—
where the rear slope exceeds 1 in 5, a guard rail must be installed with no openings except at the heads of steps or ramps; and
where the forward or front slope exceeds 1 in 8, the embankment must be stepped with plats not less than 500 mm wide and risers not greater than 230 mm high.
Guard rails must be installed to protect any fence, balustrade or railing associated with stepped or ramped standing spaces where excess pressure is expected from spectators.