NCC 2022 Volume One
Victoria variations
51 VIC variations to NCC 2022 Volume One: clauses replaced, added or deleted in Victoria. Search with VIC variations.
- VIC User group Facility type Design occupancy Number Children Closet pans 1 - 30 2 >30 Add 1 per 15 Washbasins 1 - 30 2 >30 Add 1 per 15 Note Facilities…
- VIC A2G2 Performance SolutionInsert VIC subclause A2G2(5) in clause A2G2 as follows: (5) A Performance Solution cannot be used to satisfy a relevant Performance Requirement for…
- VIC B1D6 Construction of buildings in flood hazard areasDelete clause B1D6 and insert VIC B1D6 as follows: (1) A Class 2 or 3 building, Class 9a health-care building, Class 9c building or Class 4 part of…
- VIC C2D11 Fire hazard propertiesDelete subclause C2D11(3) and insert VIC C2D11(3) as follows: (3) The requirements of (1) do not apply to a material or assembly if it is— plaster,…
- VIC D2D5 Exit travel distancesDelete subclause D2D5(4) and insert VIC D2D5(4) as follows: (4) Class 9 buildings — in a patient care area in a Class 9a building and in a…
- VIC D2D9 Width of doorways in exits or paths of travel to exitsDelete clause D2D9 and insert VIC D2D9 as follows: In a required exit or path of travel to an exit, the unobstructed width of a doorway must be not…
- VIC D3D26 Operation of latchInsert VIC subclause D3D26(6) in clause D3D26 as follows: (6) For the purposes of (1), an exit door from a children’s service which does not open to…
- VIC E1D7 Where sprinklers are required: Class 3 buildingDelete clause E1D7 and insert VIC E1D7 as follows: Sprinklers are required throughout— a Class 3 building used as a residential care building; and…
- VIC E1D13 Where sprinklers are required: occupancies of excessive hazardDelete subclause E1D13(2) and insert VIC E1D13(2) as follows: (2) For the purposes of (1), occupancies of excessive fire hazard comprise buildings…
- VIC F4D1 Deemed-to-Satisfy ProvisionsDelete subclause F4D1(1) and insert VIC F4D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements F4P1 to…
- VIC F4D4 Facilities in Class 3 to 9 buildingsDelete subclause F4D4(9) and insert VIC F4D4(9) as follows: (9) A Class 9b early childhood centre, other than a children’s service, must be provided…
- VIC F4D8 Construction of sanitary compartmentsDelete subclause F4D8(3) and insert VIC F4D8(3) as follows: (3) In an early childhood centre, other than a restricted children’s service, closet…
- VIC F4D13 First aid roomsInsert VIC clause F4D13 in clause F4D13 as follows: (1) If an assembly building, place of public entertainment (as defined in the Building Act 1993)…
- VIC F4P2 Laundry facilitiesDelete clause F4P2 and insert VIC F4P2 as follows: Laundering facilities or space for laundering facilities and the means for the sanitary disposal…
- VIC F5D1 Deemed-to-Satisfy ProvisionsDelete clause F5D1 and insert VIC F5D1 as follows: Where a Deemed-to-Satisfy Solution is proposed, Performance Requirement VIC F5P1 is satisfied by…
- VIC F5D3 Class 3, 9a and 9c residential aged care buildings – size of roomsInsert VIC clause F5D3 in clause F5D3 as follows: In a residential aged care building or residential care building— each bedroom must have a floor…
- VIC F5P1 Room or space heightsDelete clause F5P1 and insert VIC F5P1 as follows: A habitable room or space must have sufficient size to enable the room or space to fulfil its…
- VIC F5V1 Room or space heightsDelete subclause F5V1(1) and insert VIC F5V1(1) as follows: (1) Compliance with VIC F5P1 is verified only in relation to the height of a habitable…
- VIC G1D2 Swimming poolsDelete clause G1D2 and insert VIC G1D2 as follows: (1) A swimming pool associated with a children’s service, with a depth of water more than 300 mm,…
- VIC G1P2 Swimming pool access and water recirculation systemsDelete clause G1P2 and insert VIC G1P2 as follows: (1) A barrier must be provided to a swimming pool and must— be continuous for the full extent of…
- VIC G5D2 Application of PartDelete clause G5D2 and insert VIC G5D2 as follows: The Deemed-to-Satisfy Provisions of this Part apply in a designated bushfire prone area to— a…
- VIC G5D4 Protection — certain Class 9 buildingsDelete clause G5D4 and insert VIC G5D4 as follows: (1) In a designated bushfire prone area the following must comply with Specification 43: A Class…
- VIC G5F1 Construction in bushfire prone areasDelete clause G5F1 and insert VIC G5F1 as follows: A building constructed in a designated bushfire prone area— is to provide a resistance to…
- VIC G5O1 ObjectiveDelete clause G5O1 and insert VIC G5O1 as follows: The Objective of this Part is to— safeguard occupants from injury from the effects of a bushfire;…
- VIC G5P1 Bushfire resistanceDelete clause G5P1 and insert VIC G5P1 as follows: A building that is constructed in a designated bushfire prone area must be designed and…
- VIC G5P2 Additional bushfire requirements for certain Class 9 buildingsDelete clause G5P2 and insert VIC G5P2 as follows: A building that is constructed in a designated bushfire prone area and occupied by people who may…
- VIC I4D1 Deemed-to-Satisfy ProvisionsPerformance RequirementsVIC I4P1 to VIC I4P3 and relevant Performance Requirements in Sections D and F are satisfied by complying with VIC I4D2 to…
- VIC I4D2 Application of PartThe Deemed-to-Satisfy Provisions of this Part apply to Class 3 and Class 9a residential aged care buildings and Class 9c buildings.
- VIC I4D3 Doorway widthThe clear width of all bedroom entrance doorways must be not less than 900 mm. (2) The clear width of all other doorways must be not less than 800 mm.
- VIC I4D4 WindowsThe sill height of windows in habitable rooms (except kitchens) must be not more than 900 mm above the floor. (2) Openable windows must be provided…
- VIC I4D5 Grab railsGrab rails must be provided in association with every closet pan, shower or bath in accordance with AS 1428.1.
- VIC I4D6 Electronic communication systemA communication system must— contain a back-up power supply; and have a control that enables the call to be cancelled manually at the point of…
- VIC I4D7 Electrical power outletsGeneral purpose outlets must be provided as follows: In bedrooms with one occupant — two general purpose outlets provided on a minimum of two walls.…
- VIC I4P1 Communication systemsAn electronic communication system must be provided to enable residents and staff to summon assistance in habitable rooms (other than kitchens),…
- VIC I4P2 Electrical power outletsSufficient general purpose outlets must be provided for electrical appliances in bedrooms in locations that obviate the need for extension leads.…
- VIC I5D1 Deemed-to-Satisfy ProvisionsPerformance RequirementsVIC I5P1 to VIC I5P3 are satisfied by complying with VIC I5D2 to VIC I5D5.
- VIC I5D2 Application of PartThe Deemed-to-Satisfy Provisions of this Part apply to all places of public entertainment.
- VIC I5D3 Temporary tiered seating, concourses and embankmentsTemporary tiered seating, concourse and embankments must be designed and constructed as follows: Temporary tiered seating, concourse and embankments…
- VIC I5D4 Motor vehicle racingMotor vehicle racing barriers and guard rails must be provided so as to comply with the following: Motorsport Australia Track Operators Guide for…
- VIC I5D5 Sanitary and amenity facilitiesSanitary and amenity facilities in places of public entertainment must be provided as follows: In places other than buildings: One closet fixture…
- VIC I5P1 Temporary tiered seating, concourses and embankmentsTemporary tiered seating stands and embankments must be designed using engineering principles and constructed to provide for the safety of patrons…
- VIC I5P2 Motor vehicle racingEvery place of public entertainment where motor vehicle racing takes place must be provided with suitable barriers and guard rails to protect the…
- VIC I5P3 Sanitary and amenity facilitiesSufficient sanitary and amenity facilities must be provided at places of public entertainment for use by patrons. Applications VIC I5P3 applies to…
- VIC I6D1 Deemed-to-Satisfy ProvisionsPerformance RequirementVIC I6P1 and relevant Performance Requirements in Section D are satisfied by complying with VIC I6D2 and VIC I6D3.
- VIC I6D2 Application of PartThe Deemed-to-Satisfy Provisions of this Part apply to Class 9b children’s services.
- VIC I6D3 Doorways to a children’s roomA children’s room must have a doorway, or in the case of every such room accommodating more than 21 children at least two doorways as widely…
- VIC I6P1 Doorways to a children’s roomThe number and location of doorways to a children’s room must take into account the mobility of children in the event that emergency egress or entry…
- VIC S17C2 Application of automatic fire sprinkler standardsDelete clause S17C2 and insert VIC S17C2 as follows: Subject to this Specification, an automatic fire sprinkler system must comply with— for a Class…
- VIC S18C3 System requirementsDelete subclause S18C3(1) and insert VIC S18C3(1) as follows: (1) A required automatic fire sprinkler system installed in a Class 2 or 3 building…
- VIC S20C4 Smoke detection systemDelete subclause S20C4(4) and insert VIC S20C4(4) as follows: (4) In a Class 9c building provided with a smoke detection system— if the building…
- VIC S20C8 System monitoringDelete clause S20C8 and insert VIC S20C8 as follows: The following installations must be connected to a fire alarm monitoring system connected to a…