C1P3 Water efficiency
Part C1 Sanitary plumbing systems · NCC 2019: CP1.1
A sanitary plumbing system must ensure efficient use of drinking water by—
limiting water usage from—
a cistern or flushing device for a urinal, to a flush volume of not more than 2.5 litres for each—
single urinal stall; or
600 mm length of a continuous urinal wall; and
a dual flush cistern or flushing valve that is connected to a water closet pan to a flush volume of not more than—
6 and 3 litres; or
4.5 and 3 litres; or
water saving measures equivalent to or greater than those described in (a).
Applications
The flush volume of C1P3 may be within a tolerance of—
±0.5 litres for the full flush of a 6/3 litre cistern; or
+0.5 litres for the reduced flush of a 6/3 litre cistern; or
±0.2 litres for a 4.5/3 litre cistern.
Exemptions
The requirements of C1P3 do not apply to a vacuum drainage system.