Table · NCC 2022 Volume Three

Table C1V4b System 3 - Vented fixture connections

Part C1 Sanitary plumbing systems

Open Table C1V4b on NCC Online ↗
FixtureWaste Nominal Diameter (DN)Maximum length, in metres (m)Minimum gradient (%)Maximum gradient (%)Maximum number of bendsMaximum vertical drop, in metres (m)
Basin3231.8No limit23
Basin4031.8No limitNo limit3
Basin group ≤5 basins5071.84.4No limitNo limit
Basin group ≤10 basins50101.84.4No limitNo limit
Bidet3231.8No limit23
Bidet4031.8No limitNo limit3
Shower40No limit1.8No limitNo limitNo limit
Bath40No limit1.8No limitNo limitNo limit
Single urinal4031.8No limitNo limit3
>1 Single urinal50No limit1.8No limitNo limitNo limit
Trough urinal5031.8No limitNo limit3
Slab urinal6531.8No limitNo limit3
Sink - kitchen40No limit1.8No limitNo limitNo limit
Trough - laundry4031.8No limitNo limitNo limit
Domestic dishwasher40No limit1.8No limitNo limitNo limit
Domestic clothes washing machine (up to 6 kg)40No limit1.8No limitNo limitNo limit
Water closet80No limit1.8No limitNo limitNo limit
Water closet100No limit1.8No limitNo limitNo limit
Water closet group ≤8100150.9No limitNo limitNo limit
Food waste disposal unit40313.5No limitNo limit3
Sanitary napkin disposal unit4035.4No limitNo limit3
Floor waste gully50No limit1.8No limitNo limitNo limit
Floor waste gully80No limit1.8No limitNo limitNo limit
Floor waste gully100No limit1.8No limitNo limitNo limit
Small potato peeler40313.5No limitNo limit3

Table for C1V4 System 3 - Branch design

Not in NCC 2025. No Table C1V4b in NCC 2025 Volume Three.

Defined terms used