Victoria variation · NCC 2022 Volume Three

VIC C3P6 Land application systems

Part C3 On-site wastewater management · varies C3P6 Land application systems

Open on NCC Online ↗

Delete clause C3P6 and insert VIC C3P6 as follows:

(1) On-site wastewater management systems and associated land application systems must—

complete the treatment, uptake and absorption of the final effluent within the boundaries of the approved area; and

protect against internal contamination; and

provide ventilation to avoid the likelihood of foul air and gases from accumulating in the system; and

transfers wastes safely and hygienically.

(2) On-site wastewater management systems and associated land application systems must—

avoid the likelihood of the creation of unpleasant odours or the accumulation of offensive matter; and

avoid the likelihood of stormwater run-off entering the system; and

avoid the likelihood of root penetration or ingress of ground water entering the system; and

avoid the likelihood of unintended or uncontrolled discharge; and

avoid the likelihood of blockage and leakage; and

avoid the likelihood of damage from superimposed loads or ground movement; and

avoid the likelihood off effluent and foul air and gasses entering the building.

(3) The on-site wastewater management system and associated land application system continue to meet the above requirements throughout its serviceable life.

Not in NCC 2025. No VIC C3P6 in NCC 2025 Volume Three.

The national clause