Victoria variation · NCC 2022 Volume Three

VIC S41C4 Individual protection

Specification 41 Cross-connection hazards · varies S41C4 Individual protection

Open on NCC Online ↗

Delete subclause S41C4(3) and insert VIC S41C4(3) as follows:

(3) The following are High Hazard for the purpose of individual protection:

Chlorinators.

Coils and jackets in heat exchangers, in unsealed and toxic environments.

Steam calorifiers.

Steam boilers.

Antibiotic injectors (agricultural).

Bidets and toilet douche seats where the outlet in any position is not 25 mm above the overflow level of the pan.

Bidettes installed without a minimum 25 mm air gap.

Handheld bidet / douche hoses and trigger sprays.

Chemical dispensers (high toxicity).

Cooling towers.

Demineralising equipment using ion-exchange resins with acid and alkali regeneration.

Equipment used for handling, mixing, measuring and processing chemical and microbiological substances.

Fogging and cleaning sprays with chemical injection or additives.

Mixing of chemicals.

Pan washing apparatus.

Photographic developers with drinking water supply rinse tanks or mixing facilities.

Plants with auxiliary non-drinking water supplies.

Type D irrigation system injected with fertilisers, herbicides, nematicides, insecticides or weedicides.

Weed and pest spraying and water cartage tanks.

Portable and mobile tankers.

Placenta / surgical waste disposal units.

Food preparation or food storage tanks, vats or vessels (with clean-in-place systems).

Buried rainwater tank.

Not in NCC 2025. No VIC S41C4 in NCC 2025 Volume Three.