Verification Method · NCC 2022 Volume Two

H1V2 Structural robustness

Part H1 Structure · NCC 2019: V2.1.2

Open H1V2 on NCC Online ↗

(1) Compliance with H1P1(1)(c) is verified for structural robustness if (2) and (3) are complied with.

(2) The structure is assessed such that the building remains stable and the resulting collapse does not extend further than the immediately adjacent storeys upon the notional removal in isolation of—

any supporting column; or

any beam supporting one or more columns; or

any segment of a load bearing wall of length equal to the height of the wall.

(3) It is demonstrated that if a supporting structural component is relied upon to carry more than 25% of the total structure, a systematic risk assessment of the building is undertaken and critical high risk components are identified and designed to cope with the identified hazard or protective measures chosen to minimise the risk.

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two H1V2.

Clauses referred to