NCC 2022 Volume Two
Part H4 Health and amenity
36 clauses · Open on NCC Online ↗
- H4O1 Wet areasThe Objective is to safeguard the occupants from illness or injury and protect the building from damage caused by the accumulation of internal…
- H4O2 Room heightsThe Objective is to safeguard the occupants from injury or loss of amenity caused by inadequate height of a room or space.
- H4O3 FacilitiesThe Objective is to— safeguard occupants from illness caused by infection; and safeguard occupants from loss of amenity arising from the absence of…
- H4O4 LightThe Objective is to safeguard occupants from injury, illness or loss of amenity due to— isolation from natural light; and lack of adequate…
- H4O5 VentilationThe Objective is to safeguard occupants from illness or loss of amenity due to lack of air freshness.
- H4O6 Sound insulationThe Objective is to safeguard occupants from illness or loss of amenity as a result of undue sound being transmitted between adjoining dwellings.
- H4O7 Condensation and water vapour managementThe Objective is to reduce the likelihood of condensation or water vapour build-up causing illness, injury or loss of amenity for building…
- H4F1 Wet areasA building is to be constructed to avoid the likelihood of— the creation of any unhealthy or dangerous conditions; or damage to building elements,…
- H4F2 Room heightsA building is to be constructed to provide height in a room or space suitable for the intended use.
- H4F3 FacilitiesA building is to be provided with suitable— space and facilities for personal hygiene; and space or facilities for laundering; and space and…
- H4F4 LightA habitable room within a building is to be provided with openings to admit adequate natural light consistent with its function or use. (2) A space…
- H4F5 VentilationA space used by occupants within a building is to be provided with adequate ventilation consistent with its function or use.
- H4F6 Sound insulationA building element which separates dwellings is to be constructed to prevent undue sound transmission between those dwellings.
- H4F7 Condensation and water vapour managementBuilding elements in areas subject to water vapour or condensation must be constructed to reduce risks to the health of building occupants.…
- H4P1 Wet areas SATo protect the structure of the building and to maintain the amenity of the occupants, water must be prevented from penetrating— behind fittings and…
- H4P2 Room heightsA room or space must be of a height that does not unduly interfere with its intended function.
- H4P3 Personal hygiene and other facilitiesSuitable sanitary facilities for personal hygiene must be provided in a convenient location within or associated with a building, appropriate to its…
- H4P4 LightingA habitable room must be provided with windows, where appropriate to the function or use of that part of the building, so that natural light, when…
- H4P5 VentilationA space within a building used by occupants must be provided with means of ventilation with outdoor air which will maintain adequate air quality.…
- H4P6 Sound insulation NTWalls separating dwellings must, to provide insulation against the transmission of airborne sound, have a weighted standardised level difference…
- H4P7 Condensation and water vapour managementRisks associated with water vapour and condensation must be managed to minimise their impact on the health of occupants. Applications H4P7 only…
- H4V1 Room or space heightCompliance with H4P2 is verified where the height of a room or space provides an appropriate activity support level that does not unduly interfere…
- H4V2 Verification of suitable natural lightCompliance with H4P4(1) is verified for the provision of natural light in all habitable rooms when the average daylight factor for each window is…
- Table H4V3 Maximum contaminant limits for acceptable indoor air qualityPollutant | Averaging Time | Maximum Air Quality Value Carbon dioxide, CO2 | 8 hours | 850 ppm Note 1 Carbon monoxide, CO | 15 minutes | 90 ppm…
- H4V3 Verification of indoor air qualityFor a Class 1 building, compliance with H4P5(1) and H4P5(2)(a) is verified when it is determined that the building under typical conditions in use…
- H4V4 Sound insulation NTCompliance with H4P6(1) and (3) to insulate against transmission of airborne sound through walls separating dwellings is verified when it is…
- H4V5 Verification of condensation managementCompliance with Performance Requirement H4P7 is verified for a roof or external wall assembly when it is determined that a mould index of greater…
- H4D1 Deemed-to-Satisfy ProvisionsWhere a Deemed-to-Satisfy Solution is proposed, Performance Requirements H4P1 to H4P7 are satisfied by complying with H4D2 to H4D9. (2) Where a…
- H4D2 Wet areasCompliance with AS 3740 or Part 10.2 of the ABCB Housing Provisions satisfies Performance Requirement H4P1 for wet areas provided the wet areas are…
- H4D3 Materials and installation of wet area components and systemsPerformance RequirementH4P1 is satisfied for materials and the installation of wet area components and systems if— building elements in wet areas…
- H4D4 Room heightsCompliance with Part 10.3 of the ABCB Housing Provisions satisfies Performance Requirement H4P2 for room heights.
- H4D5 FacilitiesCompliance with Part 10.4 of the ABCB Housing Provisions satisfies Performance Requirement H4P3 for facilities.
- H4D6 LightCompliance with Part 10.5 of the ABCB Housing Provisions satisfies Performance Requirement H4P4 for lighting.
- H4D7 VentilationExcept for an exhaust fan from a sanitary compartment, laundry, kitchen or bathroom, Performance Requirement H4P5 is satisfied for a mechanical…
- H4D8 Sound insulationCompliance with Part 10.7 of the ABCB Housing Provisions satisfies Performance Requirement H4P6 for sound insulation.
- H4D9 Condensation management TASCompliance with Part 10.8 of the ABCB Housing Provisions satisfies Performance Requirement H4P7 for condensation management. Notes From 1 May 2023…