South Australia variation · NCC 2022 Volume Two

SA H7D2 Swimming pools

Part H7 Ancillary provisions and additional construction requirements · varies H7D2 Swimming pools

Open on NCC Online ↗

Insert SA subclause H7D2(3) in clause H7D2 as follows:

(3) For the purpose of clause 6.1.1 of AS 1926.3, a skimmer box is an outlet and must have a means of releasing the vacuum pressure should the suction become blocked.

Insert SA subclause H7D2(4) in clause H7D2 as follows:

(4) A swimming pool must have prominent and visible signage that assists persons to provide first aid and to perform cardiopulmonary resuscitation on young children.

Insert SA subclause H7D2(5) in clause H7D2 as follows:

(5) A first aid and cardiopulmonary resuscitation sign must—

be attached to the safety barrier of the swimming pool or be displayed near the swimming pool; and

be at least 300 mm by 300 mm in size; and

be made of durable and weatherproof material; and

show information about the procedures for providing first aid, including performing cardiopulmonary resuscitation.

Same wording in NCC 2025 Volume Two. See NCC 2025 Volume Two SA H7D2.