SA H7D2 Swimming pools
SA Part H7 Ancillary provisions and additional construction requirements · varies H7D2 Swimming pools
Insert SA subclause H7D2(3) in clause H7D2 as follows:
(3) For the purpose of clause 6.1.1 of AS 1926.3, a skimmer box is an outlet and must have a means of releasing the vacuum pressure should the suction become blocked.
Insert SA subclause H7D2(4) in clause H7D2 as follows:
(4) A swimming pool must have prominent and visible signage that assists persons to provide first aid and to perform cardiopulmonary resuscitation on young children.
Insert SA subclause H7D2(5) in clause H7D2 as follows:
(5) A first aid and cardiopulmonary resuscitation sign must—
be attached to the safety barrier of the swimming pool or be displayed near the swimming pool; and
be at least 300 mm by 300 mm in size; and
be made of durable and weatherproof material; and
show information about the procedures for providing first aid, including performing cardiopulmonary resuscitation.
The national clause
Other states and territories
- WA Delete subclause H7D2(1) and insert WA H7D2(1) as follows: (1) Performance Requirement H7P1 is satisfied for a…
- NSW Delete clause H7D2 and insert NSW H7D2 as follows: (1) Performance Requirement NSW H7P1 is satisfied for a swimming…
- NT Delete subclause H7D2(1) and insert NT H7D2(1) as follows: (1) This sub-clause has deliberately been left blank.…
- QLD Delete subclause H7D2(1) and insert QLD H7D2(1) as follows: (1) This sub-clause has deliberately been left blank.…
- TAS Delete subclause H7D2(2) and insert TAS H7D2(2) as follows: (2) Performance Requirement TAS H7P2 is satisfied for a…