NCC 2022 Volume Two
Western Australia variations
10 WA variations to NCC 2022 Volume Two: clauses replaced, added or deleted in Western Australia. Search with WA variations.
- WA H1D7 Roof and wall claddingDelete clause H1D7 and insert WA H1D7 as follows: (1) Diagrams depicting relevant roofing and supporting members and associated terminology used to…
- WA H9D1 Deemed-to-Satisfy ProvisionsPerformance RequirementWA H9P1 is satisfied for a building’s water use efficiency by complying with WA H9D2. (2) Performance RequirementWA H9P2 is…
- WA H9D2 Water use efficiencyAll tap fittings other than bath outlets and garden taps must be a minimum of 4 stars WELS rated. (2) All showerheads must be a minimum of 3 stars…
- WA H9D3 Swimming pool covers and blanketsAn outdoor private swimming pool or spa associated with a Class 1 building must be supplied with a cover, blanket or the like that— is deigned to…
- WA H9D4 Heated water use efficiencyAll internal heated water outlets (such as taps, showers and washing machine water supply fittings) must be connected to a heated water system or a…
- WA H9F1 Potable water demandTo reduce potable water demand, a building is to be capable of using potable water efficiently and preventing excessive loss of potable water.
- WA H9O1 Efficient use of waterThe Objective is to reduce water demand by using water efficiently and minimising water wastage.
- WA H9P1 Water use efficiencyA building must have features that, to the degree necessary, facilitate the efficient use of potable water appropriate to— the geographic location…
- WA H9P2 Water loss preventionA building, including any water holding structure, must have features that, to the degree necessary, prevent excessive loss of potable water…
- WA H9P3 Heated water use efficiencyA building must have features that, to the degree necessary, facilitate the efficient use of heated water appropriate to— the geographic location of…