11.3.3 Barriers to prevent falls

Part 11.3 Barriers and handrails · NCC 2019: 3.9.2.2

Open 11.3.3 on NCC Online ↗

(1) A continuous barrier must be provided along the side of a trafficable surface, such as—

a stairway, ramp or the like; and

a floor, corridor, hallway, balcony, deck, verandah, mezzanine, access bridge or the like; and

a roof top space or the like to which general access is provided; and

any delineated path of access to a building,

where it is possible to fall 1 m or more measured from the level of the trafficable surface to the surface beneath (see Figure 11.3.3a).

(2) The requirements of (1) do not apply to—

a retaining wall unless the retaining wall forms part of, or is directly associated with, a delineated path of access to a building from the road, or a delineated path of access between buildings (see Figure 11.3.3b); or

a barrier provided to an openable window covered by 11.3.7 and 11.3.8; or

a barrier complying with AS 1657 serving a fixed platform, walkway, stairway or ladder provided in accordance with 11.2.7(a).

Figure 11.3.3a Barriers — when required

Figure 11.3.3b Barriers — when required for retaining walls

Changed since NCC 2022. See ABCB Housing Provisions 2022 11.3.3, or show what changed.

(1) A continuous barrier must be provided along the side … barrier provided to an openable window covered by 11.3.7 and 11.3.8. 11.3.8; or a barrier complying with AS 1657 serving a fixed platform, walkway, stairway or ladder provided in accordance with 11.2.7(a). Figure 11.3.3a Barriers — when required Figure 11.3.3b Barriers — when required for retaining walls

Removed words are struck through; added words are highlighted. Comparison of the text only.

Clauses referred to

Defined terms used