Insert NT clause 13.4.6 in clause 13.4.6 as follows:

(1) Ceilings, walls, floors and any opening such as a window frame, door frame, roof light frame or the like must be constructed to minimise air leakage in accordance with (2) when forming part of the external fabric a conditioned space.

(2) Construction required by (1) must be—

enclosed by internal lining systems that are close fitting at ceiling, wall and floor junctions; or

sealed at junctions and penetrations with—

by close-fitting skirting, architraves, cornices; or

expanding foam, rubber compressive strip, or caulking, or the like.

Changed since NCC 2022. See ABCB Housing Provisions 2022 NT 13.4.6, or show what changed.