5.7.6 Weatherproofing for single leaf masonry walls
Part 5.7 Weatherproofing of masonry
(1) A waterproof coating material must be applied to all external single skin masonry walls in accordance with the following:
The coating must extend from the uppermost exposed part of the wall—
to a level adjacent to the internal finished floor level, if the external masonry wall leaf overhangs the edge of the slab by not less than 10 mm; or
50 mm below the internal floor level if no edge overhang is provided.
Acceptable external waterproof finishes are—
three coats of 100% acrylic based exterior quality gloss paint; or
one complete coat of cement based paint and two coats of 100% acrylic based exterior quality gloss paint; or
clear water repellent, provided the wall is protected by a roof overhang of not less than 1500 mm.
(2) Windows must be installed in accordance with Figure 5.7.6.
Figure 5.7.6 Typical window installation for unreinforced single skin masonry