7.4.4 Installation of gutters
Part 7.4 Gutters and downpipes · NCC 2019: 3.5.3.4
(1) Eaves gutters must be—
installed with a fall of not less than 1:500; and
supported by brackets securely fixed at stop ends, corners and at not more than 1.2 m centres; and
fitted with overflow measures capable of removing the overflow volume specified in Table 7.4.4a and Table 7.4.4b.
(2) Overflow measures in accordance with 7.4.6 and 7.4.7 are deemed to be capable of removing the overflow volume specified in those provisions.
(3) Where the overflow volume values for ridge-to-gutter lengths in Table 7.4.4a and roof catchment areas in Table 7.4.4b are not stated, interpolation may be used to determine the applicable overflow values.
(4) Valley gutters must—
be installed on a roof with a pitch more than 12.5 degrees; and
have dimensions in accordance with Table 7.4.4c for the relevant rainfall intensity; and
have minimum freeboard of not less than 15 mm; and
have a side angle of not less than 12.5 degrees.
(5) The requirement of (1)(c) does not apply to eaves gutters fixed to a verandah or an eave that is greater than 450 mm in width, which—
has no lining; or
is a raked verandah or a raked eave with a lining sloping away from the building.
Table 7.4.4a Overflow volume for continuous measure (L/s/m)
Design 5 minute duration rainfall intensity (mm/h) (from Table 7.4.3d)
Ridge to gutter length — 2 m
Ridge to gutter length — 4 m
Ridge to gutter length — 6 m
Ridge to gutter length — 8 m
Ridge to gutter length — 10 m
Ridge to gutter length — 12 m
Ridge to gutter length — 14 m
Ridge to gutter length — 16 m
150 mm/h
0.08 L/s/m
0.17 L/s/m
0.25 L/s/m
0.33 L/s/m
0.42 L/s/m
0.50 L/s/m
0.58 L/s/m
0.67 L/s/m
175 mm/h
0.10 L/s/m
0.19 L/s/m
0.29 L/s/m
0.39 L/s/m
0.49 L/s/m
0.58 L/s/m
0.68 L/s/m
0.78 L/s/m
200 mm/h
0.11 L/s/m
0.22 L/s/m
0.33 L/s/m
0.44 L/s/m
0.56 L/s/m
0.67 L/s/m
0.78 L/s/m
0.89 L/s/m
225 mm/h
0.13 L/s/m
0.25 L/s/m
0.38 L/s/m
0.50 L/s/m
0.63 L/s/m
0.75 L/s/m
0.88 L/s/m
1.0 L/s/m
250 mm/h
0.14 L/s/m
0.28 L/s/m
0.42 L/s/m
0.56 L/s/m
0.69 L/s/m
0.83 L/s/m
0.97 L/s/m
1.1 L/s/m
275 mm/h
0.15 L/s/m
0.31 L/s/m
0.46 L/s/m
0.61 L/s/m
0.76 L/s/m
0.92 L/s/m
1.1 L/s/m
1.2 L/s/m
300 mm/h
0.17 L/s/m
0.33 L/s/m
0.50 L/s/m
0.67 L/s/m
0.83 L/s/m
1.0 L/s/m
1.2 L/s/m
1.3 L/s/m
325 mm/h
0.18 L/s/m
0.36 L/s/m
0.54 L/s/m
0.72 L/s/m
0.90 L/s/m
1.1 L/s/m
1.3 L/s/m
1.4 L/s/m
350 mm/h
0.19 L/s/m
0.39 L/s/m
0.58 L/s/m
0.78 L/s/m
0.97 L/s/m
1.2 L/s/m
1.4 L/s/m
1.6 L/s/m
375 mm/h
0.21 L/s/m
0.42 L/s/m
0.63 L/s/m
0.83 L/s/m
1.0 L/s/m
1.3 L/s/m
1.5 L/s/m
1.7 L/s/m
400 mm/h
0.22 L/s/m
0.44 L/s/m
0.67 L/s/m
0.89 L/s/m
1.1 L/s/m
1.3 L/s/m
1.6 L/s/m
1.8 L/s/m
Table 7.4.4b Overflow volume for dedicated measure (L/s)
Design 5 minute duration rainfall intensity (mm/h) (from Table 7.4.3d)
Roof catchment area — 30 m2
Roof catchment area — 40 m2
Roof catchment area — 50 m2
Roof catchment area — 60 m2
Roof catchment area — 70 m2
150 mm/h
1.3 L/s
1.7 L/s
2.1 L/s
2.5 L/s
2.9 L/s
175 mm/h
1.5 L/s
1.9 L/s
2.4 L/s
2.9 L/s
3.4 L/s
200 mm/h
1.7 L/s
2.2 L/s
2.8 L/s
3.3 L/s
3.9 L/s
225 mm/h
1.9 L/s
2.5 L/s
3.1 L/s
3.8 L/s
4.4 L/s
250 mm/h
2.1 L/s
2.8 L/s
3.5 L/s
4.2 L/s
4.9 L/s
275 mm/h
2.3 L/s
3.1 L/s
3.8 L/s
4.6 L/s
5.3 L/s
300 mm/h
2.5 L/s
3.3 L/s
4.2 L/s
5.0 L/s
5.8 L/s
325 mm/h
2.7 L/s
3.6 L/s
4.5 L/s
5.4 L/s
6.3 L/s
350 mm/h
2.9 L/s
3.9 L/s
4.9 L/s
5.8 L/s
6.8 L/s
365 mm/h
3.1 L/s
4.2 L/s
5.2 L/s
6.3 L/s
7.3 L/s
400 mm/h
3.3 L/s
4.4 L/s
5.6 L/s
6.7 L/s
7.8 L/s
Table 7.4.4c Valley gutters — Dimensions
Design rainfall intensity mm/h
Sheet width (minimum, mm)
Effective depth (he), (minimum, mm)
Effective width (we), (minimum, mm)
≤200
355
32
215
>200 to ≤ 250
375
35
234
>250 to ≤300
395
38
254
>300 to ≤350
415
40
273
>350 to ≤400
435
43
292
Tables
- Table 7.4.4a Overflow volume for continuous measure (L/s/m)
- Table 7.4.4b Overflow volume for dedicated measure (L/s)
- Table 7.4.4c Valley gutters — Dimensions
State and territory variations all clauses side by side →
Clauses referred to
- 7.4.6 Acceptable continuous overflow measure
- 7.4.7 Acceptable dedicated overflow measure per downpipe