Northern Territory variation · ABCB Housing Provisions 2025

NT 13.2.5 External walls

NT Part 13.2 Building fabric · varies 13.2.5 External walls

Open on NCC Online ↗

Insert NT clause 13.2.5 in clause 13.2.5 as follows:

(1) Each part of an external wall must satisfy (2) or (3), except for—

an external wall facing the south orientation sector, as described in NT Figure 13.2.5a; and

opaque non-glazed openings such as doors (including garage doors), vents, penetrations, shutters and the like; and

glazing; and

a storey of a building complying with (4).

(2) For climate zone 1, each part of the external wall must satisfy one of the following:

Achieve a minimum Total R-Value of 1.9.

Achieve a minimum Total R-Value of 1.4 and be constructed on a flooring system that is in direct contact with the ground, such as a concrete slab-on-ground or the like.

For masonry external wall with a surface density of not less than 220kg/m2, shade the external wall of the storey with a verandah, balcony, eaves, carport or the like, which—

for an external wall facing the north and south orientation factors as described in NT Figure 13.2.5a, projects at a minimum angle of 15 degrees; and

for an external wall facing north east, east, south east, south west, west, north west orientation factors as described in NT Figure 13.2.5a, projects at a minimum angle of 45 degrees, in accordance with NT Figure 13.2.5b.

For a weatherboard, sheet clad or masonry veneer external wall —

incorporate reflective insulation with an emittance of not more than 0.05 inwards; and

be constructed on a flooring system that is in direct contact with ground, such as a concrete slab-on-ground or the like; and

shade the external wall of the storey with a verandah, balcony, eaves, carport of the like which projects at a minimum angle of 15 degrees in accordance with NT Figure 13.2.5b.

(3) For climate zone 3, each part of the external wall must satisfy one of the following:

Achieve a minimum Total R-Value of 1.9.

Achieve a minimum Total R-Value of 1.4 and be constructed on a flooring system that is in direct contact with the ground such as a concrete slab-on-ground or the like.

(4) The requirements of (1) do not apply to the storey of a building provided—

the external walls achieve a surface density of not less than 220 kg/m2; and

the external surface of the external walls achieves a solar absorptance of not more than 0.45; and

the external glazing achieves a pass when determined with the ABCB 2009 Glazing calculator; and

the external walls are shaded with a verandah, balcony, eaves, carport or the like which projects at a minimum angle of 15 degrees in accordance with NT Figure 13.2.5b; and

the habitable rooms contain ceiling fans.

Insert NT figure (13.2.5a) 13.2.5 as follows:

NT Figure 13.2.5a: Orientation sectors

Figure Notes

The direction that a wall or glazing element faces is the direction of a perpendicular line from the wall or glazing element.

This Figure is based on True North and all angles are measured clockwise from True North. Survey angles on site plans are usually marked in angles from True North. These angles can be used to establish True North for a particular site.

Magnetic North, found by a magnetic compass, varies from True North over time and by different amounts in different locations. Magnetic North is not an acceptable approximation of True North.

The eight orientation sectors shown in this Figure do not overlap at their boundaries. North sector, for example, begins just clockwise after the NNW line and ends exactly on the NNE line. The start and end of other sectors are determined in a similar way, as indicated by the outer curved arrows.

Insert NT figure (13.2.5b) 13.2.5 as follows:

NT Figure 13.2.5b: Measurement of a projection for wall shading

Figure Notes

Guttering can be considered as providing shading if attached to a shading projection.

Changed since NCC 2022. See ABCB Housing Provisions 2022 NT 13.2.5, or show what changed.

Insert NT clause 13.2.5 in clause 13.2.5 as follows: (1) Each part of an external wall must satisfy (2) … considered as providing shading if attached to a shading projection.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause