ABCB Housing Provisions 2025
Part 7.2 Sheet roofing
16 clauses · Open on NCC Online ↗
- 7.2.1 Application of Part 7.2Part 7.2 applies subject to the limitations set out in H1D7(2)(c). (2) Part 7.2 need not be complied with if H1D7(2)(a) or (b) are complied with.
- Table 7.2.2a Acceptable corrosion protection for metal sheet roofingEnvironment | Location | Minimum metal coating in accordance with AS 1397: Metallic coated steel | Minimum metal coating in accordance with AS 1397:…
- Table 7.2.2b Acceptability of contact between different roofing materials – Stainless steel accessory or fastenerCladding material | Atmosphere classification - Medium to very high as per Table 7.2.2a | Atmosphere classification - Low as per Table 7.2.2a Copper…
- Table 7.2.2c Acceptability of contact between different roofing materials – Zinc-coated steel and zinc accessory or fastenerCladding material | Atmosphere classification - Medium to very high as per Table 7.2.2a | Atmosphere classification - Low as per Table 7.2.2a Copper…
- Table 7.2.2d Acceptability of contact between different roofing materials – Zinc/aluminium coated steel or aluminium/zinc (AZ) and aluminium/zinc/magnesium (AM) coated steel accessory or fastenerCladding material | Atmosphere classification - Medium to very high as per Table 7.2.2a | Atmosphere classification - Low as per Table 7.2.2a Copper…
- Table 7.2.2e Acceptability of contact between different roofing materials – Lead accessory or fastenerCladding material | Atmosphere classification - Medium to very high as per Table 7.2.2a | Atmosphere classification - Low as per Table 7.2.2a Copper…
- 7.2.2 Corrosion protection and compatibility requirements for roofingMetal sheet roofing must be protected from corrosion in accordance with Table 7.2.2a. (2) Where different metals are used in a roofing system,…
- 7.2.3 Minimum pitches for metal sheet roofing profilesMetal sheet roofing must comply with the minimum pitch requirements for the associated roof profile in accordance with Figure 7.2.3. Figure 7.2.3…
- Table 7.2.4 Maximum roofing spans between supportsSheet roofing profile | Sheet roofing base metal thickness (mm) | Max. end span (mm) Note 1 | Max. internal span (mm) Note 1 Corrugated | 0.42 | 900…
- 7.2.4 Maximum spansMetal sheet roofing must comply with the maximum span between roofing supports in accordance with Table 7.2.4 and Figure 7.2.4. Table 7.2.4 Maximum…
- Table 7.2.5 Fixing requirements for sheet roofingSheet roofing profile | Fixing: End span | Fixing: Internal spans Corrugated | Side lap and every second rib | Side lap and every third rib Close…
- 7.2.5 Fixing of metal sheet roofingMetal sheet roofing must— be either fixed through the roofing (crest fastening) or have concealed fasteners; and be fixed at spacings in accordance…
- 7.2.6 Installation of roofing sheetsSheets must be— laid wherever possible using complete lengths from the fascia to ridge; or where a complete length cannot be laid— each run must be…
- Table 7.2.7 Fastener frequency for flashings and cappingsRoof type | Fixing frequency | Fastener type Concealed fastener roofs | Every rib | Rivets and self-drilling screws Pierced fastener roofs | Every…
- 7.2.7 Flashings and cappingsSheet metal roof flashings and cappings must comply with the following: Roof flashings and cappings must be purpose made, machine-folded sheet metal…
- 7.2.8 Water dischargeWhere an eaves gutter is provided in accordance with H2D6(1), sheets must overhang the fascia, or end batten where there is no fascia, by not less…