Table · ABCB Housing Provisions 2025

Table 7.2.4 Maximum roofing spans between supports

Part 7.2 Sheet roofing

Open Table 7.2.4 on NCC Online ↗
Sheet roofing profileSheet roofing base metal thickness (mm)Max. end span (mm) Note 1Max. internal span (mm) Note 1
Corrugated0.429001200
Close pitched trapezoidal0.4218002400
Trapezoidal0.4213001700
Concealed fasteners — narrow sheet0.4217502100
Concealed fasteners — wide sheet0.4818002100

Table Notes

Refer to Figure 7.2.4 for determination of end span and internal spans.

Thermal expansion - Maximum sheet run for pierced fixed metal roofing profiles must be not greater than 25 m when measured between the fasteners at the ends of the sheet.

Table for 7.2.4 Maximum spans

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 7.2.4.

Clauses referred to