Table · ABCB Housing Provisions 2025
Table 7.2.4 Maximum roofing spans between supports
| Sheet roofing profile | Sheet roofing base metal thickness (mm) | Max. end span (mm) Note 1 | Max. internal span (mm) Note 1 |
|---|---|---|---|
| Corrugated | 0.42 | 900 | 1200 |
| Close pitched trapezoidal | 0.42 | 1800 | 2400 |
| Trapezoidal | 0.42 | 1300 | 1700 |
| Concealed fasteners — narrow sheet | 0.42 | 1750 | 2100 |
| Concealed fasteners — wide sheet | 0.48 | 1800 | 2100 |
Table Notes
Refer to Figure 7.2.4 for determination of end span and internal spans.
Thermal expansion - Maximum sheet run for pierced fixed metal roofing profiles must be not greater than 25 m when measured between the fasteners at the ends of the sheet.
Table for 7.2.4 Maximum spans
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 7.2.4.