Table 13.3.2b Orientation sector winter exposure factor (EW) — floor in direct contact with the ground: climate zone 2

Part 13.3 External glazing

Open Table 13.3.2b on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.491.481.080.470.410.461.051.44
0.051.441.401.000.400.340.410.971.38
0.101.381.360.950.380.320.380.931.31
0.201.211.210.850.340.300.340.841.17
0.401.000.970.680.280.250.280.700.97
0.600.830.800.600.250.220.250.590.81
0.800.620.640.490.210.210.230.510.66
1.000.430.540.400.200.200.190.430.55
1.200.260.430.350.180.190.180.400.45
1.400.220.370.290.160.180.170.360.37
1.600.180.300.280.160.170.160.300.33
1.800.150.260.240.150.150.150.260.27
2.000.120.190.210.140.150.150.250.26

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.2b.