Table · ABCB Housing Provisions 2025

Table 13.3.2j Orientation sector winter exposure factor (EW) — suspended floor: climate zone 5 (lightweight wall)

Part 13.3 External glazing

Open Table 13.3.2j on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.001.611.201.000.650.480.951.191.47
0.051.561.150.910.550.400.811.091.40
0.101.561.110.860.520.390.781.051.37
0.201.300.980.770.470.350.680.941.23
0.401.190.810.640.400.300.590.771.02
0.600.970.670.520.350.270.510.660.84
0.800.780.550.460.320.250.460.590.68
1.000.640.420.360.290.230.420.500.59
1.200.430.370.330.270.220.390.410.46
1.400.320.280.270.250.210.370.390.40
1.600.220.240.250.230.180.320.320.33
1.800.180.200.210.220.180.320.280.30
2.000.140.150.200.200.180.290.270.22

Table Notes

For P/H between those shown in this Table, either use the next highest P/H or interpolate.

Table for 13.3.2 External glazing — winter

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.2j.