Table · ABCB Housing Provisions 2022
Table 13.3.2j Orientation sector winter exposure factor (EW) — suspended floor: climate zone 5 (lightweight wall)
| P/H | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 0.00 | 1.61 | 1.20 | 1.00 | 0.65 | 0.48 | 0.95 | 1.19 | 1.47 |
| 0.05 | 1.56 | 1.15 | 0.91 | 0.55 | 0.40 | 0.81 | 1.09 | 1.40 |
| 0.10 | 1.56 | 1.11 | 0.86 | 0.52 | 0.39 | 0.78 | 1.05 | 1.37 |
| 0.20 | 1.30 | 0.98 | 0.77 | 0.47 | 0.35 | 0.68 | 0.94 | 1.23 |
| 0.40 | 1.19 | 0.81 | 0.64 | 0.40 | 0.30 | 0.59 | 0.77 | 1.02 |
| 0.60 | 0.97 | 0.67 | 0.52 | 0.35 | 0.27 | 0.51 | 0.66 | 0.84 |
| 0.80 | 0.78 | 0.55 | 0.46 | 0.32 | 0.25 | 0.46 | 0.59 | 0.68 |
| 1.00 | 0.64 | 0.42 | 0.36 | 0.29 | 0.23 | 0.42 | 0.50 | 0.59 |
| 1.20 | 0.43 | 0.37 | 0.33 | 0.27 | 0.22 | 0.39 | 0.41 | 0.46 |
| 1.40 | 0.32 | 0.28 | 0.27 | 0.25 | 0.21 | 0.37 | 0.39 | 0.40 |
| 1.60 | 0.22 | 0.24 | 0.25 | 0.23 | 0.18 | 0.32 | 0.32 | 0.33 |
| 1.80 | 0.18 | 0.20 | 0.21 | 0.22 | 0.18 | 0.32 | 0.28 | 0.30 |
| 2.00 | 0.14 | 0.15 | 0.20 | 0.20 | 0.18 | 0.29 | 0.27 | 0.22 |
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table for 13.3.2 External glazing — winter
Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.2j.