Table · ABCB Housing Provisions 2025
Table 13.3.2q Orientation sector winter exposure factor (EW) — suspended floor — climate zone 8
| P/H | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 0.00 | 1.39 | 1.27 | 1.22 | 0.80 | 0.59 | 0.90 | 1.05 | 1.28 |
| 0.05 | 1.35 | 1.21 | 1.10 | 0.66 | 0.49 | 0.74 | 0.95 | 1.22 |
| 0.10 | 1.33 | 1.17 | 1.05 | 0.63 | 0.46 | 0.71 | 0.91 | 1.17 |
| 0.20 | 1.12 | 1.05 | 0.95 | 0.56 | 0.42 | 0.63 | 0.82 | 1.05 |
| 0.40 | 1.02 | 0.88 | 0.77 | 0.47 | 0.35 | 0.53 | 0.66 | 0.87 |
| 0.60 | 0.85 | 0.71 | 0.66 | 0.41 | 0.31 | 0.46 | 0.57 | 0.72 |
| 0.80 | 0.72 | 0.58 | 0.56 | 0.36 | 0.29 | 0.40 | 0.47 | 0.59 |
| 1.00 | 0.57 | 0.51 | 0.48 | 0.34 | 0.26 | 0.36 | 0.39 | 0.51 |
| 1.20 | 0.39 | 0.40 | 0.42 | 0.30 | 0.25 | 0.34 | 0.35 | 0.41 |
| 1.40 | 0.32 | 0.36 | 0.38 | 0.29 | 0.23 | 0.32 | 0.31 | 0.33 |
| 1.60 | 0.22 | 0.27 | 0.32 | 0.27 | 0.22 | 0.29 | 0.29 | 0.28 |
| 1.80 | 0.17 | 0.24 | 0.29 | 0.24 | 0.21 | 0.27 | 0.25 | 0.25 |
| 2.00 | 0.14 | 0.22 | 0.24 | 0.24 | 0.20 | 0.27 | 0.22 | 0.20 |
Table Notes
For P/H between those shown in this Table, either use the next highest P/H or interpolate.
Table for 13.3.2 External glazing — winter