Table · ABCB Housing Provisions 2025

Table 13.3.3h Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 4

Part 13.3 External glazing

Open Table 13.3.3h on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.831.131.050.680.310.991.901.46
0.050.701.050.980.630.270.911.771.33
0.100.640.950.930.590.250.851.701.22
0.200.490.830.840.530.230.761.521.05
0.400.350.630.690.440.190.621.230.81
0.600.310.480.560.360.160.531.040.59
0.800.280.360.470.320.140.450.860.47
1.000.230.290.410.270.120.390.740.39
1.200.220.250.350.240.110.350.650.33
1.400.180.220.290.220.090.330.550.27
1.600.180.190.290.200.090.290.480.26
1.800.160.170.240.180.080.250.460.22
2.000.150.160.210.150.080.240.380.21

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3h.