Table · ABCB Housing Provisions 2025
Table 13.3.3i Orientation sector summer exposure factor (ES) — suspended floor: climate zone 4
| P/H | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 0.00 | 0.79 | 1.13 | 1.12 | 0.68 | 0.29 | 0.64 | 1.05 | 1.06 |
| 0.05 | 0.66 | 1.05 | 1.05 | 0.63 | 0.25 | 0.59 | 0.98 | 0.97 |
| 0.10 | 0.61 | 0.95 | 0.99 | 0.59 | 0.23 | 0.55 | 0.94 | 0.89 |
| 0.20 | 0.52 | 0.83 | 0.90 | 0.53 | 0.21 | 0.49 | 0.84 | 0.77 |
| 0.40 | 0.43 | 0.63 | 0.74 | 0.44 | 0.17 | 0.40 | 0.68 | 0.59 |
| 0.60 | 0.36 | 0.48 | 0.59 | 0.36 | 0.15 | 0.34 | 0.58 | 0.43 |
| 0.80 | 0.32 | 0.36 | 0.50 | 0.32 | 0.13 | 0.29 | 0.47 | 0.34 |
| 1.00 | 0.29 | 0.29 | 0.44 | 0.27 | 0.11 | 0.25 | 0.41 | 0.29 |
| 1.20 | 0.25 | 0.25 | 0.37 | 0.24 | 0.10 | 0.23 | 0.36 | 0.24 |
| 1.40 | 0.23 | 0.22 | 0.31 | 0.22 | 0.09 | 0.21 | 0.30 | 0.20 |
| 1.60 | 0.21 | 0.19 | 0.30 | 0.20 | 0.08 | 0.19 | 0.26 | 0.19 |
| 1.80 | 0.19 | 0.17 | 0.26 | 0.18 | 0.07 | 0.16 | 0.26 | 0.16 |
| 2.00 | 0.19 | 0.16 | 0.22 | 0.15 | 0.07 | 0.16 | 0.21 | 0.15 |
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table for 13.3.3 External glazing — summer
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3i.