Table · ABCB Housing Provisions 2025

Table 13.3.3j Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 5 (lightweight or masonry veneer wall)

Part 13.3 External glazing

Open Table 13.3.3j on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.620.790.830.670.481.041.691.19
0.050.520.700.750.600.400.921.551.07
0.100.470.640.710.550.380.861.440.96
0.200.380.550.620.490.340.761.290.85
0.400.290.420.500.400.270.621.050.64
0.600.260.330.410.330.230.510.850.49
0.800.230.270.350.280.200.430.680.41
1.000.200.220.290.240.180.370.600.32
1.200.180.190.250.210.150.330.520.28
1.400.160.170.220.190.140.290.440.25
1.600.150.160.200.160.130.270.390.22
1.800.140.150.180.150.120.230.350.21
2.000.130.120.170.150.110.210.330.19

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3j.