Table · ABCB Housing Provisions 2025
Table 13.3.3j Orientation sector summer exposure factor (ES) — floor in direct contact with the ground: climate zone 5 (lightweight or masonry veneer wall)
| P/H | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 0.00 | 0.62 | 0.79 | 0.83 | 0.67 | 0.48 | 1.04 | 1.69 | 1.19 |
| 0.05 | 0.52 | 0.70 | 0.75 | 0.60 | 0.40 | 0.92 | 1.55 | 1.07 |
| 0.10 | 0.47 | 0.64 | 0.71 | 0.55 | 0.38 | 0.86 | 1.44 | 0.96 |
| 0.20 | 0.38 | 0.55 | 0.62 | 0.49 | 0.34 | 0.76 | 1.29 | 0.85 |
| 0.40 | 0.29 | 0.42 | 0.50 | 0.40 | 0.27 | 0.62 | 1.05 | 0.64 |
| 0.60 | 0.26 | 0.33 | 0.41 | 0.33 | 0.23 | 0.51 | 0.85 | 0.49 |
| 0.80 | 0.23 | 0.27 | 0.35 | 0.28 | 0.20 | 0.43 | 0.68 | 0.41 |
| 1.00 | 0.20 | 0.22 | 0.29 | 0.24 | 0.18 | 0.37 | 0.60 | 0.32 |
| 1.20 | 0.18 | 0.19 | 0.25 | 0.21 | 0.15 | 0.33 | 0.52 | 0.28 |
| 1.40 | 0.16 | 0.17 | 0.22 | 0.19 | 0.14 | 0.29 | 0.44 | 0.25 |
| 1.60 | 0.15 | 0.16 | 0.20 | 0.16 | 0.13 | 0.27 | 0.39 | 0.22 |
| 1.80 | 0.14 | 0.15 | 0.18 | 0.15 | 0.12 | 0.23 | 0.35 | 0.21 |
| 2.00 | 0.13 | 0.12 | 0.17 | 0.15 | 0.11 | 0.21 | 0.33 | 0.19 |
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table for 13.3.3 External glazing — summer
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3j.