Table · ABCB Housing Provisions 2025
Table 13.3.3m Orientation sector summer exposure factor (ES) — suspended floor: climate zone 5 (concrete or masonry wall)
| P/H | North | North east | East | South east | South | South west | West | North west |
|---|---|---|---|---|---|---|---|---|
| 0.00 | 0.82 | 1.04 | 1.07 | 0.72 | 0.41 | 0.78 | 1.17 | 1.10 |
| 0.05 | 0.69 | 0.91 | 0.96 | 0.64 | 0.34 | 0.69 | 1.07 | 0.99 |
| 0.10 | 0.63 | 0.84 | 0.91 | 0.59 | 0.32 | 0.65 | 1.00 | 0.89 |
| 0.20 | 0.51 | 0.72 | 0.80 | 0.53 | 0.29 | 0.57 | 0.89 | 0.79 |
| 0.40 | 0.39 | 0.55 | 0.64 | 0.43 | 0.23 | 0.47 | 0.73 | 0.59 |
| 0.60 | 0.35 | 0.44 | 0.52 | 0.35 | 0.20 | 0.38 | 0.59 | 0.46 |
| 0.80 | 0.30 | 0.35 | 0.45 | 0.30 | 0.17 | 0.32 | 0.47 | 0.38 |
| 1.00 | 0.26 | 0.29 | 0.38 | 0.26 | 0.15 | 0.28 | 0.41 | 0.29 |
| 1.20 | 0.24 | 0.25 | 0.32 | 0.23 | 0.13 | 0.25 | 0.36 | 0.26 |
| 1.40 | 0.21 | 0.22 | 0.29 | 0.20 | 0.12 | 0.22 | 0.31 | 0.23 |
| 1.60 | 0.20 | 0.21 | 0.26 | 0.17 | 0.11 | 0.20 | 0.27 | 0.20 |
| 1.80 | 0.18 | 0.19 | 0.23 | 0.16 | 0.10 | 0.17 | 0.24 | 0.19 |
| 2.00 | 0.17 | 0.16 | 0.22 | 0.16 | 0.10 | 0.16 | 0.23 | 0.18 |
Table Notes
For P/H between those in this Table, either use the next lowest P/H or interpolate.
Table for 13.3.3 External glazing — summer