Table 13.3.3m Orientation sector summer exposure factor (ES) — suspended floor: climate zone 5 (concrete or masonry wall)

Part 13.3 External glazing

Open Table 13.3.3m on NCC Online ↗
P/HNorthNorth eastEastSouth eastSouthSouth westWestNorth west
0.000.821.041.070.720.410.781.171.10
0.050.690.910.960.640.340.691.070.99
0.100.630.840.910.590.320.651.000.89
0.200.510.720.800.530.290.570.890.79
0.400.390.550.640.430.230.470.730.59
0.600.350.440.520.350.200.380.590.46
0.800.300.350.450.300.170.320.470.38
1.000.260.290.380.260.150.280.410.29
1.200.240.250.320.230.130.250.360.26
1.400.210.220.290.200.120.220.310.23
1.600.200.210.260.170.110.200.270.20
1.800.180.190.230.160.100.170.240.19
2.000.170.160.220.160.100.160.230.18

Table Notes

For P/H between those in this Table, either use the next lowest P/H or interpolate.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.3.3m.