Table 13.3.3t Summer solar heat gain factors: climate zone 3

Part 13.3 External glazing

Open Table 13.3.3t on NCC Online ↗
Type of factorFactor for a floor in direct contact with the groundFactor for a suspended floor
Room factor (RS) for a bedroom and a room which is not a conditioned space0.900.70
Level factor (LS) for all other floor levels1.701.90
Frame factor (FS) for frames with a solar absorptance of ≤ 0.400.880.88
Frame factor (FS) for frames with a solar absorptance of < 0.40 to < 0.681.001.00
Frame factor (FS) for frames with a solar absorptance of ≥ 0.681.211.21
Floor factor (for tiled or vinyl covered floor (HS)0.89Not applicable

Table Notes

Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3t.