Table · ABCB Housing Provisions 2025

Table 13.3.3u Summer solar heat gain factors: climate zone 4

Part 13.3 External glazing

Open Table 13.3.3u on NCC Online ↗
Type factorFactor for a floor in direct contact with the groundFactor for a suspended floor
Room factor (RS) for a bedroom and a room which is not a conditioned space0.350.80
Level factor (LS) for all other floor levels1.101.20
Frame factor (FS) for frames with a solar absorptance of ≤ 0.400.880.88
Frame factor (FS) for frames with a solar absorptance of > 0.40 to < 0.681.000.91
Frame factor (FS) for frames with a solar absorptance of ≥ 0.681.191.00
Floor factor (for tiled or vinyl covered floor) (HS)0.91Not applicable

Table Notes

Where a factor is listed as ‘Not applicable’, the value of the factor must be taken as 1.0.

Table for 13.3.3 External glazing — summer

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.3.3u.

Defined terms used