Table · ABCB Housing Provisions 2025
Table 13.6.2a Floor area adjustment factor
Part 13.6 Whole-of-home energy usage
| Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor | Total floor area m2 | Floor area factor |
|---|---|---|---|---|---|---|---|
| <50 | 0.0123 | 160–169 | 0.0097 | 280–289 | 0.0087 | 400–409 | 0.0080 |
| 50–59 | 0.0119 | 170–179 | 0.0096 | 290–299 | 0.0086 | 410–419 | 0.0079 |
| 60–69 | 0.0116 | 180–189 | 0.0095 | 300–309 | 0.0085 | 420–429 | 0.0079 |
| 70–79 | 0.0113 | 190–199 | 0.0094 | 310–319 | 0.0085 | 430–439 | 0.0078 |
| 80–89 | 0.0111 | 200–209 | 0.0093 | 320–329 | 0.0084 | 440–449 | 0.0078 |
| 90–99 | 0.0108 | 210–219 | 0.0092 | 330–339 | 0.0083 | 450–459 | 0.0077 |
| 100–109 | 0.0106 | 220–229 | 0.0091 | 340–349 | 0.0083 | 460–469 | 0.0077 |
| 110–119 | 0.0105 | 230–239 | 0.0090 | 350–359 | 0.0082 | 470–479 | 0.0077 |
| 120–129 | 0.0103 | 240–249 | 0.0090 | 360–369 | 0.0082 | 480–489 | 0.0076 |
| 130–139 | 0.0101 | 250–259 | 0.0089 | 370–379 | 0.0081 | 490–499 | 0.0076 |
| 140–149 | 0.0100 | 260–269 | 0.0088 | 380–389 | 0.0081 | 500 | 0.0075 |
| 150–159 | 0.0099 | 270–279 | 0.0087 | 390–399 | 0.0080 | — | — |
Table Notes
The total floor area is measured within the inside face of the external walls of the Class 1 building and includes any conditioned, attached Class 10a building.
Where values fall between ranges given, the floor area must be rounded up to the nearest whole square metres of floor area.
Table for 13.6.2 Net equivalent energy usage
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 13.6.2a.