Table · ABCB Housing Provisions 2022

Table 13.6.2a Floor area adjustment factor

Part 13.6 Whole-of-home energy usage

Open Table 13.6.2a on NCC Online ↗
Total floor area m2Floor area factorTotal floor area m2Floor area factorTotal floor area m2Floor area factorTotal floor area m2Floor area factor
<500.0123160–1690.0097280–2890.0087400–4090.0080
50–590.0119170–1790.0096290–2990.0086410–4190.0079
60–690.0116180–1890.0095300–3090.0085420–4290.0079
70–790.0113190–1990.0094310–3190.0085430–4390.0078
80–890.0111200–2090.0093320–3290.0084440–4490.0078
90–990.0108210–2190.0092330–3390.0083450–4590.0077
100–1090.0106220–2290.0091340–3490.0083460–4690.0077
110–1190.0105230–2390.0090350–3590.0082470–4790.0077
120–1290.0103240–2490.0090360–3690.0082480–4890.0076
130–1390.0101250–2590.0089370–3790.0081490–4990.0076
140–1490.0100260–2690.0088380–3890.00815000.0075
150–1590.0099270–2790.0087390–3990.0080——

Table Notes

The total floor area is measured within the inside face of the external walls of the Class 1 building and includes any conditioned, attached Class 10a building.

Where values fall between ranges given, the floor area must be rounded up to the nearest whole square metres of floor area.

Table for 13.6.2 Net equivalent energy usage

Same wording in ABCB Housing Provisions 2025. See ABCB Housing Provisions 2025 Table 13.6.2a.

Defined terms used