Table 7.3.4 Sarking requirements for tiled roofs
Part 7.3 Roof tiles and shingles
| Roof pitch | Maximum rafter/truss top chord length without sarking (mm) Note 1 |
|---|---|
| <18° | N/A Note 2 |
| ≥18° <20° | 4 500 |
| ≥20° <22° | 5 500 |
| ≥22° | 6 000 |
Table Notes
The maximum rafter/truss top chord length is measured from the topmost point of the rafter/truss i.e. the apex downwards. Where the maximum length is exceeded, sarking must be installed over the remainder of the rafter/truss top chord length towards the eave line of the roof, or equivalent where the building has no eaves.
All tiled roofs with a pitch less than 18 degrees must be provided with sarking, regardless of rafter/truss chord length.
Table for 7.3.4 Sarking
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 7.3.4.