Table · ABCB Housing Provisions 2025

Table 7.3.4 Sarking requirements for tiled roofs

Part 7.3 Roof tiles and shingles

Open Table 7.3.4 on NCC Online ↗
Roof pitchMaximum rafter/truss top chord length without sarking (mm) Note 1
<18°N/A Note 2
≥18° <20°4 500
≥20° <22°5 500
≥22°6 000

Table Notes

The maximum rafter/truss top chord length is measured from the topmost point of the rafter/truss i.e. the apex downwards. Where the maximum length is exceeded, sarking must be installed over the remainder of the rafter/truss top chord length towards the eave line of the roof, or equivalent where the building has no eaves.

All tiled roofs with a pitch less than 18 degrees must be provided with sarking, regardless of rafter/truss chord length.

Table for 7.3.4 Sarking

Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 7.3.4.

Defined terms used