Table · ABCB Housing Provisions 2025
Table 7.5.4b Stud and fixing spacings for 9.5 mm thick hardboard sheet wall cladding
Part 7.5 Timber and composite wall cladding
| Wind class | Maximum stud spacing (mm) | Maximum nail spacing within 1.2 m of the external corners of the building (mm) Note 1 | Maximum nail spacing elsewhere (mm) Note 1 |
|---|---|---|---|
| N1 | 600 | Body: 300, Edges: 150 | Body: 300, Edges: 150 |
| N2 | 600 | Body: 300, Edges: 150 | Body: 300, Edges: 150 |
| N3 | 600 | Body: 300, Edges: 150 | Body: 300, Edges: 150 |
Table Notes
Maximum nail spacing using 2.8 mm galvanised clouts or flat head nails.
Fixings must be positioned a minimum of 12 mm from the edge of the sheet and not less than 50 mm from the edge of all corners.
Fasteners must penetrate not less than 30 mm into the timber frame.
Wall cladding may be fixed through timber or metal battens attached to the wall frame in accordance with AS 1684.2, AS 1684.3, AS 1684.4 or NASH standard as appropriate (see fixing requirements for roof battens) so long as the minimum penetration into the wall frame is achieved.
Table for 7.5.4 Sheet wall cladding
Same wording in ABCB Housing Provisions 2022. See ABCB Housing Provisions 2022 Table 7.5.4b.