NSW B3D5 Water efficiency
NSW Part B3 Non-drinking water services · varies B3D5 Water efficiency
Delete clause B3D5 and insert NSW B3D5 as follows:
(1) Cisterns or flushing devices for water closets must—
Have a dual flushing mechanism; and
Be a minimum 3 Star WELS rating discharging not more than 6 litres or 4.5 litre for a full flush.
(2) Cisterns or flushing devices for urinals must—
Be a minimum 2 Star WELS rating discharging a volume of not more than 2.5 litres of each—
Single urinal stall; or
600mm length of continuous urinal wall; and
Not be set-cycled or activated by any method other than manual or use activation.
Applications
The flush volumes of B3D5(2) and B3D5(3) may be within a tolerance of—
±0.5 litres for the full flush of a 6/3 litre cistern; or
+0.5 litres for the reduced flush of a 6/3 litre cistern; or
±0.2 litres for a 4.5/3 litre cistern.
Exemptions
The requirements of B3D5(2) and B3D5(3) do not apply to a vacuum drainage system.
The requirements of B3D5(3)(b) do not apply to a programmed solenoid operated flushing system if programmed to shut down during extended periods of non-occupancy of a building.