New South Wales variation · NCC 2025 Volume Three

NSW B3P8 Water Efficiency

NSW Part B3 Non-drinking water services · varies B3P8 Water efficiency

Open on NCC Online ↗

Delete clause B3P8 and insert NSW B3P8 as follows:

Where a non-drinking water service is used for flushing toilets or urinals, efficient use of non-drinking water must be achieved by—

Incorporation of—

a cistern or flushing device for a urinal, to a flush volume of not more than 2.5 litres for each—

single urinal stall; or

600mm length of a continuous urinal wall; and

a dual flush cistern or flushing valve that is connected to a water closet pan, to a flush volume of not more than—

6 and 3 litres; or

4.5 and 3 litres; or

water saving measures equivalent to or greater than those described in (a).

Applications

The flush volumes of B3P8 may be within a tolerance of—

±0.5 litres for the full flush of a 6/3 litre cistern; or

±0.5 litres for the reduced flush of a 6/3 litre cistern; or

±0.5 litres for a 4.5/3 litre cistern

Exemptions

The requirements of B3P8 do not apply to a vacuum drainage system

New in NCC 2025. No NSW B3P8 in NCC 2022 Volume Three; it may have moved or been renumbered.

The national clause