Performance Requirement · NCC 2025 Volume Three

B3P8 Water efficiency

Part B3 Non-drinking water services

Open B3P8 on NCC Online ↗
Varied in NSW. Check the variation for your state.

Where a non-drinking water service is used for flushing of toilets or urinals, efficient use of non-drinking water must be achieved by—

incorporation of—

a cistern or flushing device for a urinal, to a flush volume of not more than 2.5 litres for each—

single urinal stall; or

600mm length of a continuous urinal wall; and

a dual flush cistern or flushing valve that is connected to a water closet pan, to a flush volume of not more than—

6 and 3 litres; or

4.5 and 3 litres; or

water saving measures equivalent to or greater than those described in (a).

Applications

The flush volumes of B3P8 may be within a tolerance of—

±0.5 litres for the full flush of a 6/3 litre cistern; or

±0.5 litres for the reduced flush of a 6/3 litre cistern; or

±0.2 litres for a 4.5/3 litre cistern.

Exemptions

The requirements of B3P8 do not apply to a vacuum drainage system.

New in NCC 2025. No B3P8 in NCC 2022 Volume Three; it may have moved or been renumbered.

State and territory variations all clauses side by side →

Defined terms used