New South Wales variation · NCC 2025 Volume Three

NSW B6P3 Water efficiency

NSW Part B6 Rainwater services · varies B6P3 Water efficiency

Open on NCC Online ↗

Delete clause B6P3 and insert NSW B6P3 as follows:

Where rainwater is used for flushing of toilets or urinals, efficient use of rainwater must be achieved by—

incorporation of—

a cistern or flushing device for a urinal, to a flush volume of not more than 2.5 litres for each—

single urinal stall; or

600 mm length of a continuous urinal wall; and

a dual flush cistern or flushing valve that is connected to a water closet pan, to a flush volume of not more than—

6 and 3 litres; or

4.5 and 3 litres; or

other water saving measures which achieve equivalent or greater efficiency than (a).

Applications

The flush volumes of B6P3 may be within a tolerance of—

±0.5 litres for the full flush of a 6/3 litre cistern; or

+0.5 litres for the reduced flush of a 6/3 litre cistern; or

±0.2 litres for a 4.5/3 litre cistern.

New in NCC 2025. No NSW B6P3 in NCC 2022 Volume Three; it may have moved or been renumbered.

The national clause