NSW B6P3 Water efficiency
NSW Part B6 Rainwater services · varies B6P3 Water efficiency
Delete clause B6P3 and insert NSW B6P3 as follows:
Where rainwater is used for flushing of toilets or urinals, efficient use of rainwater must be achieved by—
incorporation of—
a cistern or flushing device for a urinal, to a flush volume of not more than 2.5 litres for each—
single urinal stall; or
600 mm length of a continuous urinal wall; and
a dual flush cistern or flushing valve that is connected to a water closet pan, to a flush volume of not more than—
6 and 3 litres; or
4.5 and 3 litres; or
other water saving measures which achieve equivalent or greater efficiency than (a).
Applications
The flush volumes of B6P3 may be within a tolerance of—
±0.5 litres for the full flush of a 6/3 litre cistern; or
+0.5 litres for the reduced flush of a 6/3 litre cistern; or
±0.2 litres for a 4.5/3 litre cistern.