Performance Requirement · NCC 2025 Volume Three

B6P3 Water efficiency

Part B6 Rainwater services · NCC 2019: BP6.2

Open B6P3 on NCC Online ↗
Varied in NSW. Check the variation for your state.

Where rainwater is used for flushing of toilets or urinals, efficient use of rainwater must be achieved by—

incorporation of—

a cistern or flushing device for a urinal, to a flush volume of not more than 2.5 litres for each—

single urinal stall; or

600 mm length of a continuous urinal wall; and

a dual flush cistern or flushing valve that is connected to a water closet pan, to a flush volume of not more than—

6 and 3 litres; or

4.5 and 3 litres; or

other water saving measures which achieve equivalent or greater efficiency than (a).

Applications

The flush volumes of B6P3 may be within a tolerance of—

±0.5 litres for the full flush of a 6/3 litre cistern; or

+0.5 litres for the reduced flush of a 6/3 litre cistern; or

±0.2 litres for a 4.5/3 litre cistern.

Exemptions

The requirements of B6P3(a)(ii) do not apply to a vacuum drainage system.

Changed since NCC 2022. See NCC 2022 Volume Three B6P3, or show what changed.

A Where rainwater service must ensure the is used for flushing of toilets or urinals, efficient use of water rainwater must be achieved by — limiting water usage from incorporation of — a cistern or flushing device for a urinal, to … — 6 and 3 litres; or 4.5 and 3 litres; and other rainwater using fixtures and appliances, to an efficient level; or other water saving measures which achieve equivalent or greater … of B6P3(a)(ii) do not apply to a vacuum drainage system.