VIC B3D3 General requirements

VIC Part B3 Non-drinking water services · varies B3D3 General requirements

Open on NCC Online ↗

Delete clause B3D3 and insert VIC B3D3 as follows:

A non-drinking water service must be in accordance with AS/NZS 3500.1, subject to the following:

Substitute clause 9.7.1(a) as follows: 9.7.1(a) be of a type that has a removable handle.

Substitute the text of clause 9.7.1(c) as follows: 9.7.1(c) have a non-standard inlet connecting thread and a standard hose connection outlet.

Changed since NCC 2022. See NCC 2022 Volume Three VIC B3D3, or show what changed.

Delete clause B3D3 and insert VIC B3D3 as follows: A … in accordance with AS/NZS 3500.1, subject to the following: Substitute the text of clause 9.7.1(a) as follows: (a) 9.7.1(a) be of a type that has a removable handle. Substitute the text of clause 9.7.1(c) as follows: (c) 9.7.1(c) have a non-standard inlet connecting thread and a standard hose connection outlet.

Removed words are struck through; added words are highlighted. Comparison of the text only.

The national clause