NCC 2025 Volume Three
Victoria variations
35 VIC variations to NCC 2025 Volume Three: clauses replaced, added or deleted in Victoria. Search with VIC variations.
- VIC A2G2 Performance SolutionDelete clause A2G2 and insert VIC A2G2 as follows: (1) A Performance Solution is achieved by demonstrating— compliance with all relevant Performance…
- VIC A5G4 Evidence of suitability ─ Volume Three (PCA)Delete clause A5G4 and insert VIC A5G4 as follows: (1) Any product that is intended for use in contact with drinking water must comply with the…
- VIC B1D3 General requirementsDelete clause B1D3 and insert VIC B1D3 as follows: (1) A cold water service must be in accordance with AS/NZS 3500.1. (2) Notwithstanding (1), all…
- VIC B3D3 General requirementsDelete clause B3D3 and insert VIC B3D3 as follows: A non-drinking water service must be in accordance with AS/NZS 3500.1, subject to the following:…
- VIC B4D2 General requirementsDelete clause B4D2 and insert VIC B4D2 as follows: (1) Fire-fighting water services for Class 2 to Class 9 buildings and structures must comply with…
- VIC B5D7 Cross-connection hazardsDelete clause B5D7 and insert VIC B5D7 as follows: (1) The Hazard Ratings prescribed for the cross-connection hazards described in (4) to (14) must…
- VIC B6D1 Deemed-to-Satisfy ProvisionsDelete subclause B6D1(1) and insert VIC B6D1(1) as follows: (1) Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements B6P1 to VIC…
- VIC B6D8 Automatic or manual interchange deviceInsert VIC clause B6D8 in clause B6D8 as follows: An automatic or manual interchange device that allows alternate use of water from the rainwater…
- VIC B6P8 Rainwater serviceInsert VIC clause B6P8 in clause B6P8 as follows: A rainwater service must— avoid the likelihood of contamination of water within the rainwater…
- VIC C2D4 General requirementsDelete clause C2D4 and insert VIC C2D4 as follows: (1) A sanitary drainage system must be in accordance with AS/NZS 3500.2; subject to the…
- VIC C4F1 Functional statementDelete clause C4F1 and insert VIC C4F1 as follows: (1) Where liquid trade waste is generated, adequate space and facilities must be provided for the…
- VIC C4O1 ObjectiveDelete clause C4O1 and insert VIC C4O1 as follows: The Objective of this part is to— safeguard people from illness, injury or loss (including loss…
- VIC C4P1 Requirements for low risk on-site liquid trade waste management practicesDelete clause C4P1 and insert VIC C4P1 as follows: (1) A low risk liquid trade waste appliance must— be located as close as practicable to the…
- VIC E2D1 ApplicationDelete clause E2D1 and insert VIC E2D1 as follows: Performance requirements E2P1 to E2P3 are satisfied by complying with E2D2.
- VIC E2D2 General requirementsDelete clause E2D2 and insert VIC E2D2 as follows: (1) Mechanical ventilation and air-conditioning systems for buildings and structures must comply…
- VIC E2F1 Functional statement 1Delete clause E2F1 and insert VIC E2F1 as follows: Mechanical services, plant and equipment used for heating, cooling and/or ventilation of a…
- VIC E2F2 Functional statement 2Delete clause E2F2 and insert VIC E2F2 as follows: A building’s heating, cooling and/or ventilation system installation and maintenance must support…
- VIC E2O1 ObjectiveDelete clause E2O1 and insert VIC E2O1 as follows: The Objective of this Part is to— safeguard people from illness, injury or loss (including loss…
- VIC E2P1 Design, construction, installation and maintenanceDelete clause E2P1 and insert VIC E2P1 as follows: (1) Mechanical services, or plant and equipment for heating, cooling and/or ventilation must…
- VIC E2P2 Pressure equipmentDelete clause E2P2 and insert VIC E2P2 as follows: Pressure equipment used in mechanical heating, cooling or ventilation systems must avoid the…
- VIC E2P3 Microbial controlDelete clause E2P3 and insert VIC E2P3 as follows: Mechanical air-handling and cooling water systems installed in a building must control the…
- VIC E3D1 ApplicationDelete clause E3D1 and insert VIC E3D1 as follows: Performance Requirements E3P1 to E3P4 are satisfied by complying with E3D2.
- VIC E3D2 General requirementsDelete clause E3D2 and insert VIC E3D2 as follows: (1) The design, construction, installation, replacement, repair, alteration and maintenance of a…
- VIC E3F1 Functional statementDelete clause E3F1 and insert VIC E3F1 as follows: Buildings are to be provided with a roof drainage installation constructed to provide protection…
- VIC E3O1 ObjectiveDelete clause E3O1 and insert VIC E3O1 as follows: The Objective of this Part is to— safeguard people from illness, injury or loss (including loss…
- VIC E3P1 Roof drainage systemsDelete clause E3P1 and insert VIC E3P1 as follows: A roof drainage system must dispose of stormwater flows from rainfall events having an annual…
- VIC E3P2 OverflowDelete clause E3P2 and insert VIC E3P2 as follows: A roof drainage system must have an appropriate overflow device to transfer stormwater flows so…
- VIC E3P3 WatertightnessDelete clause E3P3 and insert VIC E3P3 as follows: All internal roof drainage components must be watertight.
- VIC E3P4 Design, construction and installationDelete clause E3P4 and insert VIC E3P4 as follows: (1) A roof drainage system must ensure the following— Stormwater is transferred to a point of…
- VIC E4D1 ApplicationDelete clause E4D1 and insert VIC E4D1 as follows: Performance Requirements E4P1 to E4P2 are satisfied by complying with E4D2.
- VIC E4D2 General requirementsDelete clause E4D2 and insert VIC E4D2 as follows: The design, construction, installation, replacement, repair, alteration and maintenance of…
- VIC E4F1 Functional statementDelete clause E4F1 and insert VIC E4F1 as follows: Buildings and their surroundings are to be provided with a surface drainage installation and be…
- VIC E4O1 ObjectiveDelete clause E4O1 and insert VIC E4O1 as follows: The Objective of this Part is to— safeguard people from illness, injury or loss (including loss…
- VIC E4P1 Surface drainage systemsDelete clause E4P1 and insert VIC E4P1 as follows: A surface drainage system must dispose of stormwater flows from rainfall events having an average…
- VIC E4P2 Design, construction and installationDelete clause E4P2 and insert VIC E4P2 as follows: (1) A surface drainage installation must avoid the following: Blockage and uncontrolled…