Western Australia variation · NCC 2025 Volume Three

WA B2D6 Temperature control devices

WA Part B2 Heated water services · varies B2D6 Temperature control devices

Open on NCC Online ↗

Delete clause B2D6 and insert WA B2D6 as follows:

(1) A temperature control device used to deliver heated water in accordance with WA B2D5(1)(a) must be a—

thermostatic mixing valve; or

thermostatically controlled tap.

(2) A temperature control device used to deliver heated water in accordance with WA B2D5(1)(b) must be—

thermostatic mixing valve; or

thermostatically controlled tap; or

tempering valve; or

temperature limited water heater.

(3) The required maximum delivery temperature must be achieved in accordance with AS/NZS 3500.4.

Applications

WA B2D6 applies to heated water installations to which WA B2D5 applies.

New in NCC 2025. No WA B2D6 in NCC 2022 Volume Three; it may have moved or been renumbered.

The national clause

Other states and territories