WA B2D6 Temperature control devices
WA Part B2 Heated water services · varies B2D6 Temperature control devices
Delete clause B2D6 and insert WA B2D6 as follows:
(1) A temperature control device used to deliver heated water in accordance with WA B2D5(1)(a) must be a—
thermostatic mixing valve; or
thermostatically controlled tap.
(2) A temperature control device used to deliver heated water in accordance with WA B2D5(1)(b) must be—
thermostatic mixing valve; or
thermostatically controlled tap; or
tempering valve; or
temperature limited water heater.
(3) The required maximum delivery temperature must be achieved in accordance with AS/NZS 3500.4.
Applications
WA B2D6 applies to heated water installations to which WA B2D5 applies.