Deemed-to-Satisfy Provision · NCC 2025 Volume Two

H1D4 Footings and slabs

Part H1 Structure · NCC 2019: 3.2.0, 3.2.1

Open H1D4 on NCC Online ↗
Varied in NSW. Check the variation for your state.

(1) Performance Requirement H1P1 is satisfied for the design and construction of footings and slabs if they comply with either (a) or (b):

One of the following:

AS 2870.

AS 3600.

Subject to (2), Section 4 of the ABCB Housing Provisions.

(2) Section 4 of the ABCB Housing Provisions may only be used where—

the footing is on a Class A, S or M site (classified in accordance with AS 2870) with a uniform bearing capacity; and

any slab—

is not more than 18 m long or wide; and

does not contain permanent joints excluding construction joints; and

is of a geometric shape containing only external right angles, other than a slab in (c); and

any footing and slab in (b) has not more than one re-entrant corner; and

the footing and slab are not constructed on soil classified as an aggressive soil type; and

the structure supported by the footing does not contain—

more than two trafficable floors; or

a wall height exceeding 8 m, excluding any gable; and

the footing does not support more than one concrete slab; and

the building does not include wing walls or masonry arches unless they are detailed for movement in accordance with Cement Concrete and Aggregates Australia TN 61; and

single leaf earth or stone masonry walls do not exceed 3 m in height; and

the site is considered to be normal as defined in Part 3.2 of the ABCB Housing Provisions; and

the site is not located in an alpine area; and

the building is one for which Appendix A of AS 1170.4 contains no specific earthquake design requirements.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two H1D4.

State and territory variations all clauses side by side →

Clauses referred to

Defined terms used