H1D4 Footings and slabs
Part H1 Structure · NCC 2019: 3.2.0, 3.2.1
(1) Performance Requirement H1P1 is satisfied for the design and construction of footings and slabs if they comply with either (a) or (b):
One of the following:
AS 2870.
AS 3600.
Subject to (2), Section 4 of the ABCB Housing Provisions.
(2) Section 4 of the ABCB Housing Provisions may only be used where—
the footing is on a Class A, S or M site (classified in accordance with AS 2870) with a uniform bearing capacity; and
any slab—
is not more than 18 m long or wide; and
does not contain permanent joints excluding construction joints; and
is of a geometric shape containing only external right angles, other than a slab in (c); and
any footing and slab in (b) has not more than one re-entrant corner; and
the footing and slab are not constructed on soil classified as an aggressive soil type; and
the structure supported by the footing does not contain—
more than two trafficable floors; or
a wall height exceeding 8 m, excluding any gable; and
the footing does not support more than one concrete slab; and
the building does not include wing walls or masonry arches unless they are detailed for movement in accordance with Cement Concrete and Aggregates Australia TN 61; and
single leaf earth or stone masonry walls do not exceed 3 m in height; and
the site is considered to be normal as defined in Part 3.2 of the ABCB Housing Provisions; and
the site is not located in an alpine area; and
the building is one for which Appendix A of AS 1170.4 contains no specific earthquake design requirements.