H2D8 External waterproofing
Part H2 Damp and weatherproofing · NCC 2019: 3.8.1.3
(1) Performance Requirement H2P2 is satisfied for the design and construction of external waterproofing for roofing systems on flat roofs, roof terraces, balconies and terraces and other similar horizontal surfaces located above internal spaces of a building provided—
membranes used in the external waterproofing system comply with AS 4654.1; and
the design and installation of the external waterproofing system is in accordance with AS 4654.2.
(2) The requirements of (1) apply to—
roofing systems other than those complying with H1D7(2) and (3); and
terraces, balconies and the like other than—
a concrete slab that has a minimum step-down of 50 mm below the internal floor level; or
a suspended concrete slab—
where the subfloor space is not used for habitable or non-habitable purposes; and
that has a minimum step-down of 50 mm below the internal floor level; or
spaced decking in conjunction with framing members that are suitable for external use.