Deemed-to-Satisfy Provision · NCC 2025 Volume Two

H2D8 External waterproofing

Part H2 Damp and weatherproofing · NCC 2019: 3.8.1.3

Open H2D8 on NCC Online ↗

(1) Performance Requirement H2P2 is satisfied for the design and construction of external waterproofing for roofing systems on flat roofs, roof terraces, balconies and terraces and other similar horizontal surfaces located above internal spaces of a building provided—

membranes used in the external waterproofing system comply with AS 4654.1; and

the design and installation of the external waterproofing system is in accordance with AS 4654.2.

(2) The requirements of (1) apply to—

roofing systems other than those complying with H1D7(2) and (3); and

terraces, balconies and the like other than—

a concrete slab that has a minimum step-down of 50 mm below the internal floor level; or

a suspended concrete slab—

where the subfloor space is not used for habitable or non-habitable purposes; and

that has a minimum step-down of 50 mm below the internal floor level; or

spaced decking in conjunction with framing members that are suitable for external use.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two H2D8.

Clauses referred to

Defined terms used