H7V1 Combustion appliances
Part H7 Ancillary provisions and additional construction requirements · NCC 2019: V2.7.1
Compliance with H7P3(a) and (b) is verified when—
components used within an appliance and its installation are constructed from—
heat-resistant materials for maximum operating temperatures more than 600℃, where the material complies with (c); or
heat-tolerant materials for maximum operating temperatures more than 150℃ and less than 600℃, where the material complies with (c); and
the building elements surrounding the appliance maintain their designed function and material properties inclusive of a full range of thermal movements when exposed to the heat effects of the appliance; and
a sample of the material is tested to the maximum operating temperature, specified in (a)(i) or (a)(ii) for a minimum of 96 hours; and
the tested sample, when allowed to cool, must be free from—
visible cracks and fractures; and
visible indication of de-lamination; and
linear distortion in excess of the equivalent of 10 mm per metre, and
deterioration of the appearance of any surface finish, when compared to an unheated sample.