Verification Method · NCC 2025 Volume Two

H7V1 Combustion appliances

Part H7 Ancillary provisions and additional construction requirements · NCC 2019: V2.7.1

Open H7V1 on NCC Online ↗

Compliance with H7P3(a) and (b) is verified when—

components used within an appliance and its installation are constructed from—

heat-resistant materials for maximum operating temperatures more than 600℃, where the material complies with (c); or

heat-tolerant materials for maximum operating temperatures more than 150℃ and less than 600℃, where the material complies with (c); and

the building elements surrounding the appliance maintain their designed function and material properties inclusive of a full range of thermal movements when exposed to the heat effects of the appliance; and

a sample of the material is tested to the maximum operating temperature, specified in (a)(i) or (a)(ii) for a minimum of 96 hours; and

the tested sample, when allowed to cool, must be free from—

visible cracks and fractures; and

visible indication of de-lamination; and

linear distortion in excess of the equivalent of 10 mm per metre, and

deterioration of the appearance of any surface finish, when compared to an unheated sample.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two H7V1.

Clauses referred to

Defined terms used