Tasmania variation · NCC 2025 Volume Two

TAS H7D2 Swimming pools

TAS Part H7 Ancillary provisions and additional construction requirements · varies H7D2 Swimming pools

Open on NCC Online ↗

Delete subclause H7D2(2) and insert TAS H7D2(2) as follows:

(2) Performance Requirement TAS H7P2 is satisfied for a water recirculation, disinfection and filtration system in a swimming pool with a depth of water more than 300 mm and volume of the pool exceeding 15 m3 if the system—

complies with AS 1926.3; and

provides—

the inlet and outlet openings for the purpose of water recirculation to be so located that water movement is continuous from inlet to outlet; and

the recirculation of water to be so designed that the pool contents are recirculated not less than once—

in 6 hours for an outdoor swimming pool; or

in 4 hours for an indoor swimming pool; and

the water filtration rates to not exceed 12,250 L/m2 of sand filter bed per hour, or an equivalent rate in other filter media.

Same wording in NCC 2022 Volume Two. See NCC 2022 Volume Two TAS H7D2.

The national clause

Other states and territories